beautypg.com

Installation instructions, Removal of the log guard, Fitting and removal of the firebricks – Stovax Stockton 7162 User Manual

Page 21

background image

21

INsTAllATIoN INsTRUCTIoNs

PR7218

Seal Collar with Fire Cement

Self Tapping Screw

Tee

Size

Stovax Part No.

5"

4516*

6"

4616

Cap

PR7195

600mm min

1000mm max

unsupported

Elbow with access cover

Size

Stovax Part No.

5"

4512

6"

4612

7"

4712

Flue Pipe 915mm (3ft)

Size

Stovax Part No.

5"

4502*

6"

4602

7"

4702

To chimney connection

as detailed in building

regulations

2. ReMoVAl oF THe loG GUARd

2.1 To remove the Log guard:

• Lift Log Guard clear of the supporting brackets

• Rotate to clear the sides of the door opening.

do not use appliance without the log guard in position.

3. FITTING ANd ReMoVAl oF

THe FIReBRICKs

3.1 Remove the firebricks as part of the routine maintenance.

This can be carried out without the use of tools.

3.2 Allow the appliance to cool fully before removing firebricks.

3.3 Take care when handling, as bricks can become fragile after

use. Life span depends on the type of fuels burnt and the

level of use.

• Replace damaged bricks as soon as possible

3.4 If your stove is fitted with 4 upper firebricks:

• Remove the lower 2 bricks first

• Remove the top bricks from the support rails

PR7196

Self tapping

screw at rear

Flue Pipe 915mm (3ft)

Size

Stovax Part No.

*5"

4502

6"

4602

Seal flue collar

with Fire Cement

PR7193

600mm min

1000mm max

unsupported

Elbow with access cover

Size

Stovax Part No.

5"

4512

6"

4612

7"

4712

Flue Pipe 915mm (3ft)

Size

Stovax Part No.

5"

4502*

6"

4602

7"

4702

To chimney connection

as detailed in building

regulations

1.3 Rear flue pipe installation

• Insert a tee into the flue collar

The tee piece is used as cleaning access.

• Lift appliance into position

Take care not to damage the hearth finish.

• Level using adjustable bolts, see picture 1

• Connect tee to the chimney using flue pipe

• Secure with self tapping screw

• Seal the connecting joints

Do not use a 90˚ elbow to make this connection

The Flue must be installed in accordance with