PRe-INsTAllATIoN CHeCKs
3.1 This appliance requires ventilation to supply combustion air.
Any room containing the appliance must have a permanent
air vent opening with a total free area of at least 550mm
2
per kW of appliance rated output above 5kW.
3.2 Increase air supply provisions where a room contains
multiple appliances.
3.3 If vents open into adjoining rooms or spaces there must be
an air vent of at least the same size direct to the outside.
3.4 Permanent air vents should be non-adjustable and
positioned where they are unlikely to become blocked.
3.5 Site the vents where cold draught is unlikely to cause
discomfort. This can be avoided by placing vents near
ceilings or close to the appliance, see Diagram opposite.
3. VeNTIlATIoN
- Stockton 7102 Stockton 7117 Stockton 7106 Stockton 7130 Stockton 7100 Stockton 7120 Stockton 7106lC Stockton 7101 Stockton 7163 Stockton 7116lC Stockton 7114 Stockton 7105 Stockton 7116 Stockton 7127 Stockton 7113lC Stockton 7103 Stockton 7128 Stockton 7113 Stockton 7116HC Stockton 7106HC Stockton 7104 Stockton 7119