sITe ReQUIReMeNTs
WAlls NeXT To A HeARTH
Solid, non-combustible
material e.g. masonry or
concrete
Thickness W
C
150mm
minimum
150mm
minimum
C
H
PR7204
Position of Appliance & Hearth in relation to walls
Requirement for the walls
distance of hearth from wall
'C'
distance of Appliance to wall
Min thickness of Wall
'W'
Min height of wall
'H'
0mm
0mm - 50mm
200mm
Height of appliance + 300mm
Or
1200mm from the hearth (take largest
dimension)
0mm
51mm - 300mm
75mm
0 - 150mm
150mm +
75mm
1200mm
150mm +
300mm +
No Minimum Requirement
suitable clearance should be allowed around the stove to enable the correct fitting and maintenance of the appliance.
Any clearances should be confirmed by making a site survey and a physical check of wall thickness and dimensions.
This manual is related to the following products:
- Stockton 7102 Stockton 7117 Stockton 7106 Stockton 7130 Stockton 7100 Stockton 7120 Stockton 7106lC Stockton 7101 Stockton 7163 Stockton 7116lC Stockton 7114 Stockton 7105 Stockton 7116 Stockton 7127 Stockton 7113lC Stockton 7103 Stockton 7128 Stockton 7113 Stockton 7116HC Stockton 7106HC Stockton 7104 Stockton 7119