OPERATING INSTRUCTIONS continued...

Diagnostics Mode
• To enter Diagnostics Mode, press and hold the

Program (lower right blank) button for three, (3),

seconds. When prompted, enter the code: 3-4-2-

4

using the buttons 1 – 0. Press “ENTER” (lower

right blank).


• After entering the code and pressing “ENTER,” the

Moisture Plus Part Number will be displayed briefly

and then the display will change to Diagnostics

Test – Buttonpad Test. Use the “YES” (upper right

blank) and “NO” (Preheat Bread 425) buttons to

scroll through the available diagnostic tests. Press

“ENTER” to begin the desired test.


Buttonpad Test


1. The display will show “Press the On/Off Button”.

Upon pressing the On/Off button, the LED for the

ON/OFF button will light briefly and then go out

to show that the button works.


2. The display will then prompt the user to press

the “TEMP” button (upper right blank). After

the user presses the “TEMP” (upper right blank)

button, the corresponding LED will light to show

the button works. The control will then continue

to prompt the user to press the remaining control

buttons. If the LED of the button pressed does not

light, a buttonpad problem exists. After completing

the Buttonpad Test, you will return to Diagnostics

Mode. (Press “CANCEL” at any time during the

test to return to Diagnostics Mode.)

Door Switch Test


1. After selecting Door Switch Test and pressing the

“ENTER” (lower right blank) button, the display

will show the position of each of the two switches.

Open and close the door slowly to verify the

operation of the door switches.


Proper Door Switch Activation:

• Starting with the door closed, the switches

should read:

• Slowly begin to open the door. Door switch 1

should be the first to change states:

• Next, door switch 2 should change state to:

• If the switches do not operate as stated above,

there is a problem with the door switches.

• Press “CANCEL” to exit the Door Switch Test

and return to Diagnostic Mode.