20

www.goodmanmfg.com

SS-GPC13M

SS-GPC13M

www.goodmanmfg.com

21

P

roduct

S

PecificationS

P

roduct

S

PecificationS

w

irinG

d

iaGraM

— GPC1348-60M41**

2

3

NOTE #2

NOTE #3

EM

TR

24V

208-240

3

CONTROL

240

208-240/1/60

SUPPLY VOLTAGE

C

COMP

C

S.A.

S

T1

R

L1

C

NOTE #4

H

F

RCCF

CM

T2

C

L2

BOX

H

RCCF

F

C

YL

BR

PU

2

24V

208

TR

C

BK

1

PU

COMP

CM

BR

BR

PU

4

1

PLF

PU

BK

YL

S

BK

RD

BK

5

6

2

3

C R

LVJB

RD

BL

BR

WH

GR

YL

R

C

W2

W1

G

Y

A

T

O

T

S

M

R

E

H

T

T2

T1

RD

BL

NOTE #3

PU

BL

L1

GND

C

L2

PU

BK

60

/

/

1

0

4

2

-

8

0

2

7

8

9

BL

BR

208-240/1/60 0140G01077 REV A

RD

RD

BK

BK

RD

C L G N

1 2 3

BL

BL

RD

GR

GR

GR

RD

EM

GR

SEE NOTE 2

++

1

L

3

1

2

R

W2

W1

Y

G

C

4
5
6

PLF

EM

1

C

SEE NOTE #2

IF USED

THERMOSTAT

N

G

SEE UNIT RATING PLATE FOR TYPE AND SIZE

OF OVER CURRENT PROTECTION

COMPONENT LEGEND

C

CM

COMP

EM

GND

LVJB

PLF

RCCF

SA

TR
HPS

CONTACTOR

CONDENSER MOTOR

COMPRESSOR

EVAPORATOR MOTOR

EQUIPMENT GROUND

LOW VOLTAGE JUNCTION BOX

FEMALE PLUG / CONNECTOR

RUN CAPACITOR FOR

COMPRESSOR AND FAN

START ASSIST

TRANSFORMER
HIGH PRESSURE SWITCH

FACTORY WIRING

LINE VOLTAGE

LOW VOLTAGE

OPTIONAL HIGH

VOLTAGE

FIELD WIRING

HIGH VOLTAGE

LOW VOLTAGE

NOTES:

1. REPLACEMENT WIRE MUST BE SAME SIZE AND TYPE INSULATION AS

ORIGINAL (AT LEAST 105°C) USE COPPER CONDUCTOR ONLY.

2. TO CHANGE EVAPORATOR MOTOR SPEED MOVE WHITE AND YELLOW

LEADS FROM EM"2" AND "3" TO "4" AND "5". IF BOTH LEADS ARE

ENERGIZED, THE HIGHER SPEED SETTING IS USED.

3. FOR 208 VOLT TRANSFORMER OPERATION MOVE PURPLE WIRES FROM

TERMINAL 3 TO TERMINAL 2 ON TRANSFORMER.

4. START ASSIST FACTOR EQUIPED WHEN REQUIRED

5. USE COPPER CONDUCTORS ONLY

++ USE N.E.C. CLASS 2 WIRE

2

3

SEE NOTE 5

SA (IF USED)

SEE NOTE 4

RD

YL

BK

GR

YL

4 5

WH

WH

HPS

C

HPS

WIRE CODE

BK BLACK

BL BLUE

BR BROWN

GR GREEN

OR ORANGE

PU PURPLE

RD RED

WH WHITE

YL YELLOW

BL/PNK BLUE/PINK STRIPE

YL

BL/PNK

BL/PNK

Wiring

is

subject

to

change.

Al

wa

ys

refer

to

the

wiring

diag

ram

or

the

unit

for

the

most

up-to-da

te

wiring

.

W

arning

High

Voltage:

Disconnect

all

power

bef

or

e

ser

vicing

or

installing

this

unit.

Multiple

power

sour

ces

ma

y

be

pr

esent.

F

ailur

e

to

do

so

ma

y

cause

pr

operty

damage,

per

sonal

injur

y,

or

dea

th.