beautypg.com

Wiring diagrams, Iring, Iagram – Goodman Mfg 13 SEER GPC13M User Manual

Page 20: Roduct, Pecifications, Warning, Arning

background image

20

www.goodmanmfg.com

SS-GPC13M

SS-GPC13M

www.goodmanmfg.com

21

P

roduct

S

PecificationS

P

roduct

S

PecificationS

w

irinG

d

iaGraM

— GPC1336M41**

20

WIRING DIAGRAMS

Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.

WARNING

HIGH VOLTAGE!

DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS

UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO

DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.

GPC13[36]M41*

3

CONTROL

240

FC

BR

PU

BK

RD

RD

BK

BOX

H

RCCF

F

C

YL

BR

K1

K1

M1

XFMR-C

PU

SPEED

C

BL

XFMR-R

R

G EBTDR

GR

COM

NC

NO

RD

2

24V

BL

208

C

BK

1

PU

COMP

CM

RD

RD

NOTE #3

CH

BR

BR

PU

4

1

PLF

BK

YL

S

BK

RD

BK

5

6

2

3

C R

RD

BL

BR

WH

GR

YL

R

C

W2

W1

G

Y

A

T

O

T

S

M

R

E

H

T

T2

T1

RD

BL

NOTE #4

PU

BL

L1

GND

C

L2

PU

60

/

/

1

0

4

2

-

8

0

2

HIGH

(COM)

BK

(TRANS240V)

PU

(M1) RD

BR

FC

LOW

OPTIONAL

2 SPEED

BR

EM

3 SPEED

EM

M2

7

8

9

BL

BR

BK

RD

RD

RD

RD

BK

BK

BK

BK

RD

BK

BK

RD

+

+

LVJB

SA

(IF USED)

SEE NOTE 5

PU

PU

YL

RD

BL

BL

4

2

3

1

RD

RD

PU

PU

UP

BR

SEE NOTE #6

BK

RD

YL

BL/PNK

BL/PNK

HPS

PU

208-240/1/60 0140G01235 REV. A

WIRING DIAGRAMS

21

WARNING

HIGH VOLTAGE!

DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS

UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO

DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.

Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.

GPC13[36]M41*

NOTE #4

FC

NOTE#2

EM

M1

COM

TR

24V

208-240

NO

EBTDR

208-240/1/60

SUPPLY VOLTAGE

C

COMP

C

S.A.

S

T1

R

L1

C

NOTE #5

H

F

RCCF

CM

T2

CH

C

L2

M2

208-240/1/60 0140G01235 REV. A

COMPONENT

LEGEND

BR

C

CH

CM

COMP

EBTD

R

EM

FC

GND

LVJB

PLF

RCCF

SA

TR

HPS

BLOWER INTERLOCK RELAY

CONTACTOR

CRANKCASE HEATER

CONDENSER MOTOR

COMPRESSOR

ELECTRONIC BLOWER TIME DELAY

RELAY

EVAPORATOR MOTOR

FAN CAPACITOR

EQUIPMENT GROUND

LOW VOLTAGE JUNCTION BOX

FEMALE PLUG / CONNECTOR

RUN CAPACITOR FOR

COMPRESSOR AND FAN

START ASSIST

TRANSFORMER

HIGH PRESSURE SWITCH

WIRE CODE

BK BLACK

BL BLUE

BR BROWN

GR GREEN

OR ORANGE

PU PURPLE

RD RED

WH WHITE

YL YELLOW

BL/PNK BLUE/PINK STRIPE

FACTORY WIRING

LINE VOLTAGE

LOW VOLTAGE

OPTIONAL HIGH

VOLTAGE

FIELD WIRING

HIGH VOLTAGE

LOW VOLTAGE

EBTDR

R

G

C

R

W2

W1

Y

G

C

4

5

6

EBTDR

P

L

3

2

THERMOSTAT

SEE NOTE #3

1

3

3

1

BR

2

4

SEE UNIT RATING PLATE FOR TYPE AND SIZE

OF OVER CURRENT PROTECTION

NOTES:

1. REPLACEMENT WIRE MUST BE SAME SIZE AND TYPE INSULATION AS

ORIGINAL (AT

LEAST 105°C) USE COPPER CONDUCTOR ONLY.

2. TO CHANGE EVAPORATOR MOTOR SPEED REPLACE LEAD ON EBTDR

"COM" WITH LEAD

ON EBTDR "M1" OR "M2"

3. CRANKCASE HEAT NOT SUPPLIED ON ALL UNITS.

4. FOR 208 VOLT TRANSFORMER OPERATION MOVE PURPLE WIRES

FROM TERMINAL 3

TERMINAL 2 ON TRANSFORMER.

5. START ASSIST FACTOR EQUIPPED WHEN REQUIRED

6. USE COPPER CONDUCTORS ONLY

++ USE N.E.C. CLASS 2 WIRE

P

L

F

C

HPS

NC

Wiring

is

subject

to

change.

Al

wa

ys

refer

to

the

wiring

diag

ram

or

the

unit

for

the

most

up-to-da

te

wiring

.

W

arning

High

Voltage:

Disconnect

all

power

bef

or

e

ser

vicing

or

installing

this

unit.

Multiple

power

sour

ces

ma

y

be

pr

esent.

F

ailur

e

to

do

so

ma

y

cause

pr

operty

damage,

per

sonal

injur

y,

or

dea

th.