Gallons and (Liters) of Pool/Spa water

12,000 14,000 16,000 18,000 20,000 22,000

32,000

24,000

34,000

26,000

36,000

28,000

38,000

30,000

40,000

Current salt

level

(45000) (52,500) (60,000) (67,500) (75,000) (82,500)

(120,000)

(90,000)

(127,500)

(97,500)

(135,000)

(105,000)

(142,500)

(112,500)

(150,000)

ppm

0

320

(145)

373

(170)

427

(194)

480

(218)

(242)

587

854

(267)

(388)

640

907

(291)

(412)

693

960

(315)

(436)

747

(339)

(460)

800

1067

(364)

(484)

200

300

(136)

350

(159)

400

(182)

450

(205)

500

(227)

550

800

(250)

(363)

600

850

(273)

(385)

650

900

(295)

(408)

700

950

(318)

(430)

750

1000

(341)

(453)

400

280

(127)

327

(148)

373

(170)

420

(191)

467

(212)

513

747

(233)

(339)

560

793

(255)

(360)

607

840

(276)

(382)

653

887

(297)

(403)

700

933

(318)

(424)

600

260

(118)

303

(138)

347

(158)

390

(177)

433

(197)

477

693

(217)

(317)

520

737

(236)

(337)

563

780

(256)

(358)

607

823

(276)

(378)

650

867

(297)

(398)

800

240

(109)

280

(127)

320

(145)

360

(164)

400

(182)

440

640

(200)

(291)

480

680

(218)

(310)

520

720

(236)

(328)

560

760

(255)

(346)

600

800

(273)

(364)

1000

220

(100)

257

(117)

293

(133)

330

(150)

367

(167)

403

587

(183)

(267)

440

623

(200)

(283)

477

660

(217)

(300)

513

697

(233)

(317)

550

733

(250)

(333)

1200

200

(91)

233

(106)

267

(121)

300

(136)

333

(152)

367

533

(167)

(243)

400

567

(182)

(258)

433

600

(197)

(274)

467

633

(212)

(289)

500

667

(227)

(304)

1400

180

(82)

210

(95)

240

(109)

270

(123)

300

(136)

330

480

(150)

(218)

360

510

(164)

(232)

390

540

(177)

(246)

420

570

(191)

(259)

450

600

(205)

(263)

1600

160

(73)

187

(85)

213

(97)

240

(109)

267

(121)

293

427

(133)

(195)

320

453

(145)

(207)

347

480

(158)

(219)

373

507

(170)

(231)

400

533

(182)

(243)

1800

140

(64)

163

(74)

187

(85)

210

(95)

233

(106)

257

373

(117)

(169)

280

397

(127)

(180)

303

420

(138)

(190)

327

443

(148)

(201)

350

467

(159)

(211)

2000

120

100

80

60

20

40

(55)

(45)

(36)

(27)

(9)

(18)

140

117

23

47

(64)

(53)

(11)

(21)

160

133

27

53

(73)

(61)

(12)

(24)

180

150

30

60

(82)

(68)

(14)

(27)

200

167

33

67

(91)

(76)

(15)

(30)

220

320

183

267

37

53

73

107

(100)

(145)

(83)

(121)

(17)

(24)

(33)

(48)

240

340

200

283

40

57

80

113

(109)

(154)

(91)

(129)

(18)

(26)

(36)

(51)

260

360

217

300

43

60

87

120

(118)

(163)

(98)

(137)

(20)

(27)

(39)

(54)

280

380

233

317

47

63

93

127

(127)

(172)

(106)

(144)

(21)

(29)

(42)

(57)

300

400

250

333

50

67

100

133

(136)

(181)

(114)

(152)

(23)

(30)

(45)

(60)

(32)

80

(36)

90

(41)

100

(45)

110

160

(50)

(73)

120

170

(55)

(77)

130

180

(59)

(81)

140

190

(64)

(86)

150

200

(68)

(90)

93

(42)

107

(48)

120

(55)

133

(61)

147

213

(67)

(98)

160

227

(73)

(104)

173

240

(79)

(110)

187

253

(85)

(117)

200

267

(91)

(123)

2200

3000

2800

2400

3200

Ideal

Ideal

Ideal

Ideal

Ideal

Ideal

Ideal

Ideal

Ideal

Ideal

Ideal

Ideal

Ideal

Ideal

Ideal

2600

3400

OK

OK

OK

OK

OK

OK

OK

OK

OK

OK

OK

OK

OK

OK

OK

OK

OK

POUNDS and (Kg) OF SALT NEEDED FOR 3200 PPM

3600+

Dilute

Dilute

Dilute

Dilute

Dilute

Dilute

Dilute

Dilute

Dilute

Dilute

Dilute

Dilute

Dilute

Dilute

Dilute

10,000

8,000

(37,500)

213 267

(97)

(121)

200 250

(91)

(114)

187 233

(85)

(106)

173 217

(79)

(98)

160 200

(73)

(91)

147 183

(67)

(83)

133 167

(61)

(76)

120 150

(55)

(68)

107 133

(48)

(61)

93 117

(42)

(53)

80 100

67 83

53 67

40

50

13 17

27 33

(36)

(45)

(30)

(38)

(24)

(30)

(18)

(23)

(6)

(8)

(12)

(15)

Ideal

Ideal

Dilute

Dilute

(30,000)

3

The pool’s chemistry must be balanced BEFORE activating the Pro Logic’s optional chlorinator function. NOTE: If

the pool does not have new water, add metal remover and non-copper based algaecide to the pool, per manufacturer’s

instructions. This ensures a quick, troublefree transfer to the Pro Logic system.

Salt

(When using optional chlorinator function )

Salt Level

Use the chart on the top of page 4 to determine how much salt in pounds or (Kgs) should be added to reach the

recommended levels. Use the Pool Sizing Formula on page 4 (measurements are in feet/gallons and meters/liters) if

pool size is unknown.

The operating salt level is between 2700-3400 PPM (parts per million) with 3200 PPM being optimal. Before adding

any salt, test the salt level. This is especially important for retrofit installation to older pools where all of the chlorine

added to the pool over time is ending up as salt. If the level is low, determine the number of gallons in the pool and add

salt according to the chart below. A low salt level will reduce the efficiency of the sanitization and result in low chlorine

production. A high salt level can cause the Pro Logic to stop chlorinating. The salt in your pool/spa is constantly

recycled and the loss of salt throughout the swimming season should be minimal. This loss is due primarily to the

addition of water because of splashing, backwashing, or draining (because of rain). Salt is not lost due to evaporation.

28

Valve3 Interlock

If “Enabled”, this feature will override the function (timeclock or in-floor cleaner) selected above and turn
the valve off when: the filter pump is off, first 3 minutes of filter pump operation (allows the pump to prime
and get water flowing), or for the first 3 minutes after solar turns on (allows air in the solar panels to be
purged). Interlock is not available for solar or super chlorinate.

Valve3 External Input Interlock

When Valve3 External Input Interlock is enabled, the Valve3 output will be forced off when the external
input is active. This will have precedence over freeze protection. Valve3 External Input Interlock is not
available for solar and super chlorinate.

Valve3 Freeze Protection

This function protects the pool and plumbed equipment against freeze damage. If Freeze Protection is
enabled and the AIR temperature falls sensor falls below the selected freeze temperature threshold, the Pro
Logic will turn on the valve to allow circulation of the water. IMPORTANT: this only enables operation of
the valve3 output during freeze--see the “Filter Pump Config.” menu to enable freeze protection for the
main circulation system.

6B Spa Config.

+ to view/change

6B A, Button 1

Pool/Spa

Select 6B Spa

A

Push to access the 6 Button Spa Side Remote options

Rotates between System Off, Pool/Spa, Filter, Lights, Heater1,

Aux1 and Aux2

Rotates between all available remotes

Move to previous/next configuration menu

Move to previous/next menu item or next configuration menu

Move to next menu item

if AQL-SS-6B is connected

Select 6B Spa
This menu only appears if more than one AQL-SS-6B is detected at power up. Select which of the available
remote controls (A, B or C) is to be configured.

6B A, Button 1
This menu allows the user to map each button of the AQL-SS-6B to one of the standard Pro Logic
functions. The default selections are: Button 1 - Pool/Spa, Button 2 - Filter, Button 3 - Lights, Button 4 -
Heater1, Button 5 - Aux1 and Button 6 - Aux2.

Remote Menus

Enabled

Toggle between Enabled (default) and Disabled Remote Menus
Move to previous/next configuration menu

This feature will prevent unauthorized access to the Settings, Timers, and Configuration menus from any
of the Pro Logic’s remote display/keypads. When disabled, the remote display/keypads will only show the
default menu and allow on/off control via the pushbuttons. Note that the function of the Pro Logic’s built-
in display/keypad is unchanged by this selection. Once disabled, the only way to enable “Remote
Menus” is to use the local display/keypad.

All Timeclocks

7-day

Move to previous/next configuration menu

Toggle between 7-day (default) and Weekend/Weekday time options

This selection affects ALL of the timeclock logic in the Pro Logic. If “7-day” is selected, each timeclock will
have one set of turn-on/turn-off settings that operate every day of the week. If “Weekend/Weekdays”
option is selected then the user can enter one set of turn-on/turn-off times for the weekend (fixed as
Saturday/Sunday) and another set of turn-on/turn-off times for weekdays (Monday through Friday).