CSG14 Series Gigabit Converter Switch

Installation and User Guide (09/09)


iv

www GarrettCom com

.

.

Electrical Safety requirements:

1.

This product is to be installed Only in Restricted Access Areas

(Dedicated Equipment Rooms, Electrical Closets, or the like).

2.

48VDC products shall be installed with a readily accessible disconnect

device in the building installation supply circuit to the product.

3.

This product shall be provided with a maximum 10A DC Listed fuse or

circuit breaker in the supply circuit when connected to a 48V

centralized

source.

4.

The external power supply for DC units shall be Listed, Direct Plug In

power unit, marked Class 2, or listed ITE Power Supply, marked LPS,

which has suitably rated output voltage (i.e. 24VDC or 48VDC) and suitable

rated output current.

5.

Product does not contain user replaceable fuses. Any internal fuses can

ONLY be replaced by GarrettCom personnel through the RMA process.

This manual is related to the following products: