Commissioning – Stovax STUDIO 8700CFCHEC User Manual
Page 22
22
7. COMMISSIONING
7.1 Check the flame picture
7.2 Check the gas pressure
7.3 • Close all door and windows in the room
• Ignite the Studio and operate on maximum for 5 minutes
• Position a lighted smoke match just inside the draught
diverter opening and check all smoke is drawn in along the
opening
If there is any doubt:
• Run the appliance for a further 10 minutes and repeat
the test, Diagram 40
40
AR0757
If there are any extractor fans in the room or adjacent
rooms, the test must be repeated with the fans running on
maximum.
IF SPILLAGE PERSISTS, DISCONNECT THE APPLIANCE
AND SEEk EXPERT ADVICE.
For future reference, record the installation details on the
Commissioning Sheet on page 3.
COMMISSIONING