7. COMMISSIONING

7.1 Check the flame picture

7.2 Check the gas pressure

7.3 • Close all door and windows in the room

• Ignite the Studio and operate on maximum for 5 minutes

• Position a lighted smoke match just inside the draught

diverter opening and check all smoke is drawn in along the

opening

If there is any doubt:

• Run the appliance for a further 10 minutes and repeat

the test, Diagram 40

40

AR0757

If there are any extractor fans in the room or adjacent

rooms, the test must be repeated with the fans running on

maximum.

IF SPILLAGE PERSISTS, DISCONNECT THE APPLIANCE

AND SEEk EXPERT ADVICE.

For future reference, record the installation details on the

Commissioning Sheet on page 3.

COMMISSIONING