BEFORE YOU CALL FOR SERVICE…
Problem
Possible Causes
What To Do
Water contains tiny
New filter cartridges contain
• Turn on a water faucet and allow these harmless carbon particles to
black particles
activated carbon, which is
purge from the cartridge. Turn off the faucet when the water is clear.
a harmless black powder.
Water has air bubbles
Air in system after installation.
• Will go away after water runs for a while.
and is cloudy
Indicator light on the
Three months usage has occurred.
• Replace filter cartridge and batteries in the timer.
timer is flashing
This is the maximum life of the
• Reset timer by holding down the reset button for 5 seconds.
filter cartridges.
Indicator light on the
Timer operating normally.
• Light flashed 5 times when reset. It will not flash again until 3 months
timer is not working
have passed.
• No action required.
Batteries may need to be
• Observe orientation markings on the holder and install correctly.
replaced or they may have been
Replace batteries if they are old.
installed incorrectly.
Timer not reset
Reset button has built-in time delay.
• Reset timer by holding down reset button for 5 seconds.
Chlorine taste and /or
The filter cartridge is no
• Replace FXHTC filter cartridge.
odor in the product water
longer removing chlorine
from the water supply.
FXHSC Filter (pleated paper) is
• If chlorine reduction is desired, change to FXHTC filter cartridge.
installed, which does not remove
chlorine.
Fittings are leaking
Not enough sealing tape
• Unscrew fitting from head and remove old sealing tape. Add new sealing
between fitting and head
on fittings.
tape to the fitting.
Fitting has become loose.
• Install mounting bracket if not used.
• Tighten fittings with wrench.
Water dispenses
The filter has been installed
• A three-month change-out period is recommended.
very slowly
for too long.
Replace filter cartridge.
The filter cartridge has
• High sediment levels can cause premature clogging.
become clogged.
Replace filter cartridge.
Fittings are leaking
Piping system is not
• This fitting is designed for 3/4
″
copper pipe only. Consult a licensed
between fitting and pipe
3/4
″
copper pipe.
plumber if other piping is used.
Compression nut has become loose.
• Tighten the compression nut with wrench while holding other half of
fitting with second wrench.
Canister is difficult
Inlet water supply still on.
• Shut off inlet water and push red pressure relief button.
to remove
Internal water pressure has not
• Push red pressure relief button.
been relieved.
Leaking between
Seal O-ring is missing or damaged.
• Replace O-ring (Part #HDRING)
canister and head
Canister is loose.
• Turn off water supply.
• Press red pressure relief button.
• Tighten canister with canister wrench.
Troubleshooting Tips
Save time and money! Review the chart below