BEFORE YOU CALL FOR SERVICE…

Problem

Possible Causes

What To Do

Water contains tiny

New filter cartridges contain

Turn on a water faucet and allow these harmless carbon particles to

black particles

activated carbon, which is

purge from the cartridge. Turn off the faucet when the water is clear.

a harmless black powder.

Water has air bubbles

Air in system after installation.

Will go away after water runs for a while.

and is cloudy

Indicator light on the

Three months usage has occurred.

Replace filter cartridge and batteries in the timer.

timer is flashing

This is the maximum life of the

Reset timer by holding down the reset button for 5 seconds.

filter cartridges.

Indicator light on the

Timer operating normally.

Light flashed 5 times when reset. It will not flash again until 3 months

timer is not working

have passed.

No action required.

Batteries may need to be

Observe orientation markings on the holder and install correctly.

replaced or they may have been

Replace batteries if they are old.

installed incorrectly.

Timer not reset

Reset button has built-in time delay.

Reset timer by holding down reset button for 5 seconds.

Chlorine taste and /or

The filter cartridge is no

Replace FXHTC filter cartridge.

odor in the product water

longer removing chlorine
from the water supply.

FXHSC Filter (pleated paper) is

If chlorine reduction is desired, change to FXHTC filter cartridge.

installed, which does not remove
chlorine.

Fittings are leaking

Not enough sealing tape

Unscrew fitting from head and remove old sealing tape. Add new sealing

between fitting and head

on fittings.

tape to the fitting.

Fitting has become loose.

Install mounting bracket if not used.

Tighten fittings with wrench.

Water dispenses

The filter has been installed

A three-month change-out period is recommended.

very slowly

for too long.

Replace filter cartridge.

The filter cartridge has

High sediment levels can cause premature clogging.

become clogged.

Replace filter cartridge.

Fittings are leaking

Piping system is not

This fitting is designed for 3/4

copper pipe only. Consult a licensed

between fitting and pipe

3/4

copper pipe.

plumber if other piping is used.

Compression nut has become loose.

Tighten the compression nut with wrench while holding other half of

fitting with second wrench.

Canister is difficult

Inlet water supply still on.

Shut off inlet water and push red pressure relief button.

to remove

Internal water pressure has not

Push red pressure relief button.

been relieved.

Leaking between

Seal O-ring is missing or damaged.

Replace O-ring (Part #HDRING)

canister and head

Canister is loose.

Turn off water supply.

Press red pressure relief button.

Tighten canister with canister wrench.

Troubleshooting Tips
Save time and money! Review the chart below
first and you may not need to call for service.