STEP-BY-STEP INSTALLATION INSTRUCTIONS
FEED WATER SUPPLY
Check and comply with local plumbing codes
as you plan, then install a cold feed water supply fitting. For new home installation using
standard plumbing fittings, see Fig. 2A below. A typical installation for existing homes using the saddle valve is shown in Fig. 2B below.
A. PREFERRED INSTALLATION
1.
Turn off the cold water supply.
2.
Complying with plumbing codes, install a fitting on the cold
water pipe to adapt 1⁄4² OD tubing. A typical connection is
shown in Fig. 2A. Make sure a shutoff valve is used.
B. OPTIONAL HOME INSTALLATION
When codes permit
NOTE:
Codes in the state of Massachusetts require installation by
a licensed plumber and do not permit the use of the saddle valve.
For installation, use plumbing code 248-CMR of the
Commonwealth of Massachusetts.
1.
Turn off the cold water supply and attach saddle valve as
shown in Fig. 2B.
DANGER: To protect yourself from serious injury or fatal
shock, use a battery powered hand drill only to make the
hole. Do not use an electric drill.
2.
Close the water supply/saddle valve by turning the handle
clockwise.
3.
Open the main water supply valve and several house faucets to
purge air from the system. Close faucets when water runs
smoothly.
3
Fig. 2B.
OPTIONAL WATER SUPPLY CONNECTION
(using saddle valve)
TYPICAL LOCATION
PREFERRED WATER SUPPLY CONNECTION
(using compression fitting)
Pre-drill
1⁄4² hole
Seal—make sure
the seal is in place
Clamp X
Nut (2)—not
required if
holes in
clamp are
threaded
Valve
Handle
Nut
Cold
water
1⁄4² compression fitting
Insert
Cold
water
pipe
1⁄4² tubing to inlet
Ferrule
Ferrule
Insert
Use to connect
the tubing
❵
Clamp Z
Fig. 2A.