Performance data sheet, Hoja de datos de funcionamiento – GE GXSL55F User Manual
Page 5
Performance Data Sheet.
SmartWater Filtration System GXSL55F
Using Filter FQSLF
■ This System has been tested according to NSF/ANSI 42 and 53 for the
reduction of the substances listed below. The concentration of the indicated
substances in water entering the system was reduced to a concentration
less than or equal to the permissible limit for water leaving the system, as
specified in NSF/ANSI 42 and 53.
■ Actual performance may vary with local water conditions.
■ Do not use with water that is microbiologically unsafe or with water of
unknown quality without adequate disinfection before or after the system.
Systems certified for cyst reduction may be used on disinfected waters that
may contain filterable cysts.
Hoja de datos de funcionamiento.
Cartucho FQSLF de sistema de filtración
GE SmartWater GXSL55F
■ Este sistema se ha sometido a las pruebas NSF/ANSI 42 y 53 a fin de reducir
las sustancias presentadas a continuación. Se redujo la concentración
de las sustancias indicadas en el agua que ingresan en el sistema a una
concentración menor o igual al limite permitido para el agua que sale del
sistema, como se especifica en NSF/ANSI 42 y 53.
■ El desempeño real puede variar de acuerdo a las condiciones locales
del agua.
■ No use con agua que sea microbiológicamente insegura o de calidad
desconocida sin una desinfección adecuada del sistema antes o después.
Los sistemas certificados para la reducción de esporas pueden ser usados
en agua desinfectada que podría contener esporas filtrables.
Standard No. 42: Aesthetic Effects / Estándar No. 42: Efectos estéticos
USEPA
Influent
Influent
Effluent
% Reduction
Min. Required
Parameter
MCL
Challenge Concentration
Average
Average
Maximum
Average
Minimum
Reduction
USEPA
Calidad del
Promedio
Effluyente
% de reducción
Reducción
Parámetro
MCL
influyente concentración
influyente
Promedio
Máximo
Promedio
Mínimo
mínima necesaria
Chlorine/Cloro
—
2.0 mg/L ± 10%
1.89 mg/L
<0.05 mg/L
0.06 mg/L
>97.29%
96.84%
≥50%
T & O
—
—
—
—
—
—
—
—
Particulate**/
—
≥ 10000 particles/
5700000 #/mL
30583 #/mL
69000 #/mL
99.52%
98.94%
≥85%
Partículas
partículas/mL
Standard No. 53: Health Effects / Estándar No. 53: Efectos relativos a la salud
USEPA
Influent
Influent
Effluent
% Reduction
Min. Required
Parameter
MCL
Challenge Concentration
Average
Average
Maximum
Average
Minimum
Reduction
USEPA
Calidad del
Promedio
Effluyente
% de reducción
Reducción
Parámetro
MCL
influyente concentración
influyente
Promedio
Máximo
Promedio
Mínimo
mínima necesaria
Turbidity/Turbidez
1 NTU***
11 ± 1 NTU***
10.73 NTU
0.311 NTU
0.49 NTU
97.08%
95.15%
0.5 NTU
Cysts/Quistes
99.95% red.
Min. 50000L
166500 #/L
<1
<1
>99.99%
>99.99%
>99.95%
Asbestos/Amianto
99% red.
10
7
and/y 10
8
fibers/fibras/L;
155 MF/L
<1
<1
>99.99%
>99.99%
99%
fibers/fibras >10 µm
long/de largo
Lead/Plomo,
0.015 mg/L
0.15 mg/L ± 10%
0.152 mg/L
<0.001
<0.001
>99.34%
>99.29%
0.01 mg/L
pH 6.5
Lead/Plomo,
0.015 mg/L
0.15 mg/L ± 10%
0.148 mg/L
<0.001
<0.001
>99.31%
>99.29%
0.01 mg/L
pH 8.5
Mercury/Mercurio,
0.002 mg/L
0.006 mg/L ± 10%
0.006 mg/L
0.00024
0.0005
98.72%
99.31%
0.002 mg/L
pH 6.5
Mercury/Mercurio,
0.002 mg/L
0.006 mg/L ± 10%
0.006 mg/L
0.0007
0.0013
87.37%
79.63%
0.002 mg/L
pH 8.5
Lindane
0.0002 mg/L
0.002 mg/L ± 10%
0.002 mg/L
0.000025
0.00002
98.97%
98.89%
0.0002 mg/L
Toxaphene
0.003 mg/L
0.015 ± 10%
0.015 mg/L
<0.001
<0.001
93.23%
91.67%
0.003 mg/L
2,4-D
0.0017 mg/L
0.021 mg/L ± 10%
0.222 mg/L
0.01422 mg/L
0.059 mg/L
93.14%
70.50%
0.0017 mg/L
Atrazine
0.003 mg/L
0.009 mg/L ± 10%
0.00886 mg/L
<0.002
<0.002
77.33%
76.61%
0.003 mg/L
*Tested using a flow rate of 0.78 gpm (2.95 l/min); pressure of 60 psig; pH of 7.5 ± 0.5; temp. of 68° ± 5°F (20° ± 3°C) / Probado utilizando una tasa de flujo de 0,78 gpm (2,95 l/min); presión de 60 psig; pH
de 7,5 ± 0,5; temp. de 68° ± 5° F (20° ± 3° C)
**Measurement in particles/mL. Particles used were 0.5–1 microns. / Medición en partículas/mL. Las partículas usadas eran de 0,5–1 micrón.
***NTU—Nephelometric Turbidity Units / NTU—unidades de turbidez nefelométrica
Operating Specifications / Especificaciones de operación
Capacity: certified for up to 1200 gallons (4,542 l); up to six months / Capacidad: certificado para hasta 1200 galones (4542 l); hasta seis meses
Pressure requirement: 35–120 psi (2.8–8.2 bar) / Requerimientos de presión: 35–120 psi (2,8–8,2 bar)
Temperature: 33–100°F (0.6–38°C) / Temperatura: 33°–100° F (0,6°–38° C)
Flow rate: 0.78 gpm (2.95 l/min) / Tasa de flujo: 0,78 gpm (2,95 l/min)
Replacement Filter Canisters/Estimated Replacement Costs
FQSLF—Replacement filter canister $30–35
For replacement parts, call toll-free 800.626.2002.
Repuesto de los cartuchos de los filtros/Costos estimados de reposición
FQSLF—Repuesto del cartucho del filtro $30–35
Para repuestos, llame gratis al 800.626.2002 (EE.UU.).