beautypg.com

Required tools and materials, Installation – GE Merlin User Manual

Page 8

background image

8

THE BASIC REVERSE OSMOSIS SYSTEM

Rev B

REQUIRED TOOLS AND MATERIALS

Adjustable wrench, and larger adjustable jaw pliers or pipe wrench
to fit sink drain

Saw for cutting drain pipe

Slotted and Phillips head screwdrivers

Tubing cutters

Electric drill and bits for cutting the faucet mounting hole

Note that some sinks will have a pre-drilled hole with a plug for the
faucet.

INSTALLATION

STEP 1: Install cold water supply valve

STEP 2: Install drain adapter

STEP 3: Install faucet

STEP 4: Make tubing connections

STEP 5: Install RO assembly

STEP 6: Put system into operation

STEP 1: INSTALL COLD WATER SUPPLY VALVE

Comply with local plumbing codes. A typical connection using a water
supply valve is shown. The feed water valve is not included with
system. Contact supplier for this item.

Water Supply Valve

Cold water pipes vary in size and style. The installer will determine
type of valve that will be used. Install a valve on the cold water supply
pipe to adapt 1/2-inch OD tubing. If threaded fittings are used, be sure
to use pipe joint compound or Teflon tape on outside threads.

Turn the valve off.

NOTE:

Consult a licensed plumber if you are not familiar with

plumbing procedures.

NOTE:

Be sure to turn off the water supply and open a low faucet to

drain the pipe.