beautypg.com

System performance rating, System specifications and operating parameters – GE Merlin User Manual

Page 27

background image

DIMENSIONS

27

Rev B

SYSTEM PERFORMANCE RATING:

Average System Recovery means the percentage of the influent water to the membrane portion of
the system that is available to the user as reverse osmosis treated water when operated as designed
(without a pressurized storage tank).

Average System Efficiency rating means the percentage of the influent water to the system that is
available to the user as reverse osmosis treated water under operating conditions that approximate
typical daily usage.

Efficiency rating is identical to recovery rating when the system is tested without a storage tank or
when a storage tank is bypassed.

SYSTEM SPECIFICATIONS AND OPERATING PARAMETERS

Minimum and Maximum Operating Conditions

Actual system performance will vary depending on varying water temperature and pressure, TDS
levels and inlet water chemistry. Operating the system in water conditions outside the minimum or
maximum operating parameters may result in reduced system performance and membrane element
life.

System manufactured by:

GE Infrastructure
Water & Process Technologies

5720 N. Glen Park Road
Milwaukee, WI 53209-4454
U.S.A.

Direct spare parts and service inquiries to the system’s installing dealer.

Product Water Production:

748 Gallons perday (2,831 Liters per day)

Average System Recovery:

23.70%

Average System Efficiency:

23.70%

Inlet Water Condition

Minimum

Maximum

Pressure

40 psi (2.76 bar)

80 psi (5.52 bar)

Temperature

40

°

F (4.44

°

C)

100

°

F (37.78

°

C)

TDS

50 mg/L

2,000 mg/L

Hardness

0 mg/L

171 mg/L

Chlorine

0.0 mg/L

1.0 mg/L

Iron

0.0 mg/L

0.1 mg/L

Manganese

0.0 mg/L

0.05 mg/L

PH

4.0

10.0