beautypg.com

Connecting opener power cables, Master operator, Slave operator – GTO 2502 User Manual

Page 24: Step 4, Step 6, Step 5

background image

20

Step 4

Insert the stripped power cable wires into the appropriate
terminals on the MASTER operator terminal block. The
green wire should be inserted into the GRN terminal, the
blue wire into BLU, the orange wire into ORG, black
wire into BLK, and the red wire into the RED terminal.

Tighten the set screws against the end of the wires. A
dab of petroleum jelly on each terminal will help prevent
corrosion.

Correct

Wrong

Wrong

Wire

Terminal 

Block

Terminal 

Block

Terminal 

Block

Wire

Wire

Connecting Opener Power Cables

MASTER Operator

Step 6

Strip approximately 3/16" of insulation from each wire
of the 40 foot power cable. Twist each exposed wire
tightly. Insert the second opener power cable upward
through the right strain relief (if necessary, loosen the
sealing nut). Thread approximately 4" of wire into the
control box. Retighten strain relief (on the black sheath
of the power cable) until the power cable locks into
place.

Insert the stripped wires of the power cable into the
appropriate terminals on the SLAVE operator terminal
block. The green wire should be inserted into the

GRN

terminal, the blue wire into BLU, the orange wire into

ORG, black wire into BLK, and the red wire into the

RED terminal.

Tighten the set screws against the end of the wires.

Step 5

Review the Installation Overview illustration on page 11 before proceeding.

Cut a slot into the driveway to accommodate PVC conduit (not provided). The buried conduit will protect the 40 foot power
cable from automobile tires, lawn mower blades, weed eaters, and grazing animals.

Pull the 40 foot second opener power

cable through the conduit and secure them into the slot in the driveway.

SLAVE Operator

Power Cable from the Operator

RECEIVER

SWITCH

MASTER INPUTS

GRN

WHT

BLUE

BRN

ORG

RED

BLK

COM

COM

CYCLE

CLOSE

SAFETY

EXIT/

OPEN

SHADOW

LOOP
CLOSE

EDGE

OPEN

EDGE

BLK

GRN

RED

STALL FORC

E

MIN

MAX

SWITCH

RELA

Y OUT

SLA
VE INPUTS

GRN

WHT

BL

UE

BRN

ORG

RED

BLK

NC
RL

Y-COM

NO

MASTER INPUTS

GRN

WHT

BL

UE

BRN

ORG

RED

BLK

COM

COM

Power Cable from the

Slave Operator Arm

This manual is related to the following products: