220v operation, 110v operation – Grizzly G1019Z User Manual
Page 7
Model G1019Z 14" Bandsaw
-5-
220V Operation
The motor supplied with the G1019Z can be oper-
ated at either 110V or 220V. The motor comes
prewired for 110V.
If converting to operate at 220V, a suitable 220V
plug must be wired in. Refer to the wiring diagram
insert supplied with this manual. When operating
at 220V, we recommend using a NEMA-style 6L-
15 plug and outlet.
See Figure 2
. Check the elec-
trical codes in your area for specifics on wiring
requirements.
Under normal use, the motor draws approximate-
ly 6 amps @ 220V. We recommend a 10 amp cir-
cuit breaker. This should be satisfactory for nor-
mal use while providing enough protection
against damage caused by power surges.
SECTION 2: CIRCUIT REQUIREMENTS
110V Operation
The G1019Z Bandsaw motor is prewired to oper-
ate at 110V.
See Figure 1.
Under normal 110V
use, the motor draws approximately 12 amps. We
recommend a 15 amp circuit breaker or a 15 amp
slow-blow fuse.
We also recommend that the circuit you use
should be dedicated, (i.e., the G1019Z should
provide the only draw from that circuit). If frequent
circuit failures occur when using the bandsaw,
contact our Service Department or your local
electrical contractor.
Figure 1.
Typical 110V 3-prong plug and outlet.
Figure 2.
Typical 220V 3-prong plug and outlet.