Table 3.2c: Maximum segment lengths for common network configurations

Number

of Hubs

Repeater

Hop Count

Max. User

Segment

Lengths (m)

Max. Inter-

Repeater (Cascade)

Length (m)

Notes

1

1

100.0

N/A.

All ports TX

2

2

100.0

5.0

All ports TX

2

2

92.0

20.0

All ports TX

2

2

79.5

1.0

1 hub T4, 1 hub TX and T4
(class I repeater), all cables
Cat. 5

3+

3

60.0

1.0

All ports TX


3.3 Powering the Magnum DS50 / DS60

Magnum DS50 / DS60 Dual-speed

Hub Plus incorporates an internal universal

power supply and has a recessed male IEC

connector for the AC power cord at the right-

rear. A six-foot 115vac 60Hz power cord is

supplied with each unit shipped within the United States and Canada.

AC Power: Auto-ranging

100-240 vac, 47-63 Hz

Each DS50 / DS60 auto-ranging power supply supports installation environments where

the AC voltage is from 100 to 240 volts with an input frequency between 47 and 63 Hz, and

consumes a maximum of 20 watts.

In order to power down the unit, simply unplug either end of the power cable.

NOTE: The DC Power Supply option, -48VDC and 24VDC are described in APPENDIX B.