Magnum DS50 / DS60s Dual Speed Hubs Installation and User Guide (06/02)

Each Magnum DS50 / DS60 Dual-speed Hub Plus is shipped with two mounting

brackets (and screws), to allow the unit to be mounted in nearly any desired orientation or

position. The brackets are attached to the unit’s case with one of the metal screws for each

bracket. It is recommended that the brackets be attached to two opposite corners on the unit.

The brackets should be attached to the Magnum DS50 / DS60 through the round hole of the

bracket. When properly attached, the brackets will extend slightly below the base of the unit to

allow clearance for the rubber feet.


3.1.2

Optional mounting methods, DIN-rail and E-Stand

A)

For DIN-rail mounting, a kit is needed that uses the metal mounting brackets (see

3.1.1 above) to attach DIN-rail clips that hold the unit in a vertical position, Ethernet

cables attaching at the bottom. For additional information on DIN mounting, email

[email protected]

B)

The E-Stand provides a

vertical mounting option for

the DS50 / DS60s. When

horizontal placement is not

possible or desirable (such as

when the unit is placed on a

carpeted floor, which would

potentially block air flow

from the cooling fan), the E-

Stand offers a convenient

installation option. Simply

align the rectangular cut-out on the E-Stand with the air vent on either side of the

DS50 / DS60. The E-Stand also allows the DS50 / DS60 unit to be securely mounted

via two screws that connect through the E-Stand and into the side of the unit.

M

a

gn

um

D

S

60

P

e

rs

on

a

l H

u

b

P

lus

G

A

R

R

E

T

T

=

x

1

0

1

0

0

UP

L

IN

K

Mb

/s

L

IN

K

R

X

L

IN

K

R

X

L

IN

K

R

X

L

IN

K

R

X

L

IN

K

R

X

RX

LI

N

K

CO

L

PW

R

1

2

34

5

6

Screw holes

Rectangular
cut-out
(Air Vent)

3.2

Ethernet Media, connections and Specifications

The Magnum DS50 / DS60 Dual-speed Hub Plus can be connected to the following

three media types: 100BASE-TX, 10BASE-T and 100BASE-FX. CAT 5 cables should be used

when making 100BASE-TX connections. When the ports are used as 10BASE-T ports, CAT 3

may be used. In either case, the maximum distance for unshielded twisted pair cabling is 100

meters (328 ft). For fiber port 100BASE-FX multi-mode, 50/125 or 62.5/125 microns cabling

can be used, whereas for single-mode, 9/125 microns cabling should be used. Fiber cabling

supports much longer cable distance and higher bandwidths as compared to copper wiring.