PRE-INSTALLATION CHECKS
* When measured from the top of the appliance to the top of the flue, with no horizontal sections
and a maximum of 4 bends with angles of less than 45°
† May be 125mm (5") if burning smokeless or low volatiles fuel only
1. VENTILATION
1.1 This appliance requires ventilation to supply combustion air.
Any room containing the appliance must have a permanent
air vent opening with a total free area of at least 550mm
2
per kW of appliance rated output above 5kW.
1.2 Increase air supply provisions where a room contains
multiple appliances.
1.3 If vents open into adjoining rooms or spaces there must be
an air vent of at least the same size direct to the outside.
1.4 Permanent air vents should be non-adjustable and
positioned where they are unlikely to become blocked.
1.5 Site the vents where cold draught is unlikely to cause
discomfort. This can be avoided by placing vents near
ceilings or close to the appliance, see Diagram opposite.
Without flue liner system Round
(diameter)
Without flue liner system Square
(diameter)
With Liner or Factory made system (diameter)
installed in accordance with manufacturers instructions
All products
Flue/Chimney Size
Flue/Chimney
(*minimum height)
Model
Stockton 7 Inset Convector - Model: 7125
Stockton 8 Inset Convector - Model: 7126
Stockton
7
mm
150
inch
6
mm
150
inch
6
m
4.5
feet
13
mm
135 x 135
inch
5
1/2
x 5
1/2
Stockton
8
150
6
150
6
4.5
13
135 x 135
5
1/2
x 5
1/2
Do not connect to systems containing large voids or over 230mm (9”) square