beautypg.com

Troubleshooting tips, Before you call for service – GE GXRM10G User Manual

Page 16

background image

Consumer Support

Tr

oubleshooting T

ips

Operating Instructions

Safety Instructions

Installation Instructions

Before you call for service…

Problem

Possible Causes

What To Do

Sounds you might hear

Running water from the unit

This is normal.

to a drain.

Water has air bubbles

Air in system after installation.

Will go away after water runs for a while.

and is cloudy

Chlorine taste and/or

The ppm of chlorine in your

If the water supply contains more than 2.0 ppm of

odor in the Reverse

water supply exceeds maximum

chlorine, additional filtering of the water supply to the

Osmosis product water

limits and has destroyed the

Reverse Osmosis is needed. Correct this condition before

Reverse Osmosis membrane.

doing maintenance on the Reverse Osmosis system.

The prefilter is no longer

Replace the Reverse Osmosis membrane cartridge,

removing chlorine from

flow control, screen, prefilter and postfilter.

the water supply.

Other taste and/or odor

High quality product water

This is normal.

may have a different taste
than what you’re used to.

Low water usage.

Completely drain system and allow to refill.

Contamination in product

Use sanitizing procedures.

water storage.

Prefilter and postfilter

Replace the prefilter and postfilter. If taste and odor

need to be changed and/or

persists, replace the Reverse Osmosis cartridge, flow

the Reverse Osmosis cartridge

control and screen.

needs to be changed.

Water leaking from

Drain side of faucet air gap

Inspect and eliminate restriction or plug. It is important

faucet air gap hole

(3/8

tubing) plugged, restricted

that there are no dips, loops or low spots in the drain line

or incorrectly connected to the

from the faucet air gap to the drain pipe. Refer to the

drain point.

Filtration Drain Connection Installations section, for proper
drain connection. If drain line adapter was used as the
drain point, periodic inspection/cleaning is recommended.

System makes product

This is normal.

Water flow rate will be lower than your regular faucet.

water slowly

Water supply to the Reverse

Increase water pressure, precondition the water, etc.,

Osmosis system not within

as needed to conform to specification guidelines before

specifications.

doing maintenance on the Reverse Osmosis system.

Prefilter cartridge plugged

Replace the prefilter and postfilter. If rate does not

with sediments and/or the

increase, replace the Reverse Osmosis cartridge, flow

Reverse Osmosis cartridge

control and screen.

plugged with sediments.

Faucet light blinking

Prefilter and postfilter

Replace filters. Don’t forget to sanitize the system when

need replacing.

replacing filters.

Timer was not reset when filters

Remove and replace battery in faucet base.

were replaced.

Six months have passed

Battery may be dead.

Replace battery. NOTE: Replacing battery resets the

and faucet light is not

six-month timer, so be sure to replace prefilter and

blinking

postfilter if it is time to do so.

Battery may have been

Any time the battery is removed and reinserted, the

removed recently.

six-month timer starts over again. Do not remove battery
unless you wish to restart the timer.

Troubleshooting Tips
Save time and money! Review the chart first and you may
not need to call for service.

16