System assembly, Caution – GE GXRM10G User Manual
Page 10
Installation Instructions
REVERSE OSMOSIS SYSTEM ASSEMBLY
AND STORAGE TANK INSTALLATION
NOW THAT YOUR REVERSE OSMOSIS SYSTEM
IS INSTALLED…SANITIZE!
Sanitize upon installation and after servicing
inner parts, including replacement of prefilter,
postfilter and the Reverse Osmosis cartridge.
It is important to wash hands with anti-
bacterial soap before handling inner parts of
the system. See the Sanitization section.
CAUTION:
If installing unit in new
construction, ensure that house plumbing is
flushed thoroughly before opening the water
supply valve. Also, before sanitizing, be sure
to remove all cartridges as described in the
Sanitization section. Chlorine will destroy the
Reverse Osmosis cartridge.
Hold the Reverse Osmosis assembly up
to the wall surface where you will install it.
Mark locations for the screws. The arrows
on the top of the bracket show the location
of the screw holes.
1
Connect the tubing to the storage tank: Run
the length of 3/8
″ orange tubing from the
tee fitting on the Reverse Osmosis module
to the tank inlet fitting.
5
Wood screws are included for fastening
to a wood surface. Provide other screws
as needed.
2
Hang the Reverse Osmosis assembly
on the screws.
3
Apply pipe thread sealing tape to the tank
fitting. Insert into tank threads. Tighten with
a wrench.
4
10
Storage
tank
To faucet
Supply line
Orange tubing
2
″ minimum clearance
for changing cartridges