Magnum 700X Mini-Concentrators Installation and User Guide (05/98)

GARRETT

29

Figure 3.12.2e: Local Isolation with Bridge Port Module

3. Bridge Transparency: The BPMs are transparent to both the user and the

application software.

4. LINK and Traffic Status: The Magnum BPM-TP and BPM-FST indicate link

integrity with an LED. This LINK LED is normally lit. An unlit LINK LED indicates

a broken cable or loss of power at some point in the segment. All BPMs have FWD-I

and FWD-X status LEDs. The FWD-I LED flashes when packets are forwarded into

the local segment. The FWD-X LED flashes when packets are forwarded out of the

local segment.

5. Self-test Diagnostics: A BPM requires about 15 seconds upon power-up before

bridging services are available. During this time, the BPM performs an internal self-

test.

4.3

Powering the Magnum 700X Mini-Concentrator

The Magnum 700X incorporates an internal universal power supply, and has a female

IEC connector for the AC power cord at the right-rear. A six foot 115 vac power cord is supplied

with each unit. (Except units being shipped from the GCI factory outside the United States and

Canada will not include a 115 vac power cord.)

The Magnum 700X supports installation environments where the AC voltage is from

90 to 260 volts with a power input frequency between 47 and 63 Hz, and will consume no more

than a maximum of 40 watts. The power connector is located on the back of the unit. In order to

eu

Magnum 700X

Mini-Concentrator

GARRETT

Local User Ports with Heavy Local Traffic,
Connected to Magnum RPMs

Network Connection to
External Network via BPM