5 Fault Finding

The following tables provide information on possible

malfunctions during the operation of the solar cylinder as well

as their cause and remedy.
NOTE: Only use original spare parts from Glow-worm. for the

replacement of parts. We recommend making a maintenance

agreement.

Malfunction

Cause

Remedy

Solar cylinder
The cylinder cools down at night. The

flow and return temperatures vary after

switching off the pump. The collector

temperature is higher than the air

temperature at night.

. The gravity brake is blocked.

. Check the position of the blue handle.

. Check the gravity brake for tightness

(jammed cuttings, particles of dirt in the

sealing face).

3. Do not connect the solar heat

exchanger directly, rather pull the supply

pipes downwards and then upwards to

the collector (syphon supports the gravity

brake) or install a -port valve, which

is switched on at the same time as the

pump.

. One-pipe circulation in the event of

short pipe networks with low pressure

loss.

Install a gravity brake (as close as

possible to the cylinder).

Reheating is not working. The boiler

runs for a short time, goes off and then

back on again. This is repeated until the

cylinder is at its target temperature.

. Air in the reheating heat exchanger.

Bleed the reheating heat exchanger.

. Heat exchanger surface area too small. Compare the specifications of the boiler

manufacturer with those of the cylinder

manufacturer. The problem may be able

to be solved by a higher setting of the

flow temperature at the boiler.

Only cold or lukewarm water comes out

of the taps.

. Cold and hot water connections on the

cylinder have been mixed up.

Turn off the cold water supply, then

let water flow out via the hot water

connection. Only a few litres of water

flow out if the connection is laid correctly.

The inlet of the hot water draw-off pipe

then rests in the air space; no further

emptying is possible. If the entire solar

cylinder runs empty via the hot water

connection, the connections have been

laid incorrectly. Change the connections!

. Hot water thermostat mixer set too low. Increase the setting.
3. Solar heating insufficient; boiler does

not reheat.

External control device faulty.

Air in the reheating heat exchanger

Cylinder temperature sensor defective.

Check whether the boiler is working.

Check whether the external control

device is working.

Check whether the two port valve is in the

hot water position.

Replace the two port valve.

Bleed the reheating heat exchanger.

Check the thermal cut out and reset it.

Replace the cylinder thermostat.

Table 5. Fault Finding