4.12 SERVICE SCHEDULE

ATTENTION: It is recommended that all service work

be performed by the nearest Dealer.

SYSTEM/COMPONENT PROCEDURE

FREQUENCY

X = Action

Inspect

Change

Clean

W = Weekly

R = Replace as Necessary

M = Monthly

* = Notify Dealer

Y = Yearly

if Repair is Needed.

FUEL

Fuel lines and connections*

X

M

LUBRICATION

Oil level

X

M

Oil

X

Every 200 hours**, or 24

hours of continuous use,

or

2Y

Oil filter

X

Every 200 hours**, or 24

hours of continuous use,

or

2Y

COOLING

Enclosure louvers

X

X

W

BATTERY

Remove corrosion,

X

X

M

ensure dryness

Clean and tighten

X

X

M

battery terminals

Check charge state

X

R

EVERY 6 M

Electrolyte level

X

R

EVERY 6 M

(unsealed batteries only)*

ENGINE AND MOUNTING

Air cleaner

X

R

2Y or 200 hours

Spark plug(s)

X

R

2Y or 200 hours

GENERAL CONDITION

Vibration, Noise, Leakage,

X

M

Temperature*

COMPLETE TUNE-UP*

TO BE COMPLETED BY

2Y or 200 hours

A

DEALER

* Contact the nearest dealer for assistance if necessary.

** Change oil and fi lter after fi rst eight (8) hours of operation and then every 200 hours thereafter, or 2 years, which-

ever occurs fi rst. Change sooner when operating under a heavy load or in a dusty or dirty environment or in high
ambient temperatures.