beautypg.com

Vert-i-pak, Electrical data – Friedrich 24,000 BTU/h User Manual

Page 4

background image

2

Vert-I-Pak

®

R-410A

23 1/8”

23 1/8”

47 1/4”

Vert-I-Pak

®

ELECTRIC HEATER SIZE

25 = 2.5 KW
34 = 3.4 KW
50 = 5.0 KW
75 = 7.5 KW
100 = 10.0 KW

L

T

R

4

3

K

24

A

E

V

R

E

B

M

U

N

L

E

D

O

M

ENGINEERING CODE

OPTIONS

VOLTAGE

NOMINAL CAPACITY

DESIGN SERIES

SERIES

* Single circuit from main box. Based on copper wire 100' or less, single insulated conductor at 60 º C.

See chart, page 14

NOTE:

.4” water

Heater Watts

2500/2050

3400/2780

5000/4090

7500/6135

10000/8180

2500/2050

3400/2780

5000/4090

7500/6135

10000/8180

Voltage

Heating BTU/h

8500/7000

11600/9500

17000/13900 25598/20939 34130/27918

8500/7000

11600/9500

17000/13900 25598/20939 34130/27918

Heating Current (Amps)

10.9/9.9

14.8/13.4

21.7/19.7

32.6/29.5

43.5/39.3

10.9/9.9

14.8/13.4

21.7/19.7

32.6/29.5

43.5/39.3

Minimum Circuit Ampacity

17.2/15.9

22.1/20.3

30.7/28.1

44.3/40.3

57.9/52.7

17.2/15.9

22.1/20.3

30.7/28.1

44.3/40.3

57.9/52.7

Branch Circuit Fuse (Amps)

25

25

30

45

60

25

25

30

45

60

LRA - Compressor (Amps)

34.8

34.8

34.8

34.8

34.8

34.8

34.8

34.8

34.8

34.8

Cooling Current (Amps)

10.0/10.4

10.0/10.4

10.0/10.4

10.0/10.4

10.0/10.4

10.6/10.9

10.6/10.9

10.6/10.9

10.6/10.9

10.6/10.9

Basic heater Size

2.5 Kw

3.4 Kw

5.0 Kw

7.5 Kw

10.0 Kw

2.5 Kw

3.4 Kw

5.0 Kw

7.5 Kw

10.0 Kw

Power Connection

Recommended Branch

Circuit Wire Sizes* AWG -

American Wire Gauge

10

1 0

10

6

4

10

10

10

6

4

HARD WIRED

HARD WIRED

VEA24K

VHA24K

230/208

230/208

Electrical Data