3 main burner malfunctions (cont.) – Frymaster BK1814 User Manual
Page 44
Frymaster BK1814 Series Gas Fryers
Chapter 7: Troubleshooting
7-3
7.3 Main Burner Malfunctions (cont.)
D. Fryer will not reach the temperature setting and/or runs erratically.
1. Incorrect location of sensor probe or defective temperature sensor.
2. Loose wiring/wire connection
E. Fryer oil temperature cannot be controlled; fryer runs at high-limit temperature.
1. Defective temperature probe; Call Authorized Service Agent.
User- Replaceable Parts
Part Number
Descripton
803-0380
Basket Rack, 16x13.7
108-1872
Vat cover 21.38 x 19.43
823-7619 Splash
guard
803-0278 L-shaped
brush
803-0197 Fryers’
friend
823-7770
Basket hanger (single and used with RAM unit left or right)
823-7771
Basket hanger, two battery, larger 1814 pots
823-7772
Basket hanger, three battery, smaller pot in middle
823-7773
Basket hanger, two battery with larger 1814 pot left
823-7774
Basket hanger, two battery unit with larger 1814 pot on right
823-7895
Single pot, non-filter unit
106-4309
Door, left or right
210-8077 Door
handle
810-1105 Door
magnet
Filter Pan Components
823-7425 Crumb
tray
810-3541 Hold-down
ring
200-8003
Sana grid screen
823-7294 Filter
pan
810-2805 Caster
803-0289 Filter