beautypg.com

4 gas connections (cont.) – Frymaster BK1814 User Manual

Page 17

background image

Frymaster BK1814 Series Gas Fryers

Chapter 3: Installation

3-3

3.4 Gas Connections (cont.)

Gas Supply Type and Pressure

Gas Supply Type

Gas Supply Pressure

Natural Gas

6-10" W.C. (Dynamic)

Propane (LP) Gas

11-13" W.C. (Dynamic)

DANGER

When pressure-testing incoming gas supply lines, disconnect the fryer from the gas

line if the test pressure is ½" PSI [3.45 kPa (14 inches W.C.)] or greater to avoid

damage to the fryer’s gas piping and gas valve(s).

DANGER

All connections must be sealed with a joint compound suitable for the gas being

used and all connections must be tested with a solution of soapy water before

lighting any pilots.

Never use matches, candles, or any other ignition source to check for leaks. If gas

odors are detected, shut off the gas supply to the appliance at the main shut-off

valve and immediately contact the local gas company or an authorized service

agency for service.

DANGER

"Dry-firing" your unit will cause damage to the frypot and can cause a fire. Always

ensure that melted shortening, cooking oil or water is in the frypot before firing the

unit.

A. Rigid Connections: Check any installer-supplied intake pipe(s) visually and clean

threading chips, or any other foreign matter before installing into a service line. If the
intake pipes are not clear of all foreign matter, the orifices will clog when gas pressure is
applied. Seal pipe joints with a sealant resistive to LP gas. When using thread compound
on gas piping, use very small amounts and only on male threads. Use a pipe thread
compound that is not affected by the chemical action of LP gases. DO NOT apply thread
compound to the first two pipe threads—doing so will cause clogging of the burner
orifices and control valve.

B. Manual shut-off valve: This gas service supplier-installed valve must be installed in the

gas service line ahead of the fryers in the gas stream and in a position where it can be
reached quickly in the event of an emergency.

C. Regulating Gas Pressure: The fryer and shut-off valve must be disconnected from the gas

supply during any pressure testing of the system.

NOTE: External gas regulators are not normally required on this fryer. A safety control
valve protects the fryer against pressure fluctuations. If the incoming pressure is in
excess of ½" PSI (3.45 kPa/35 mbar), a step-down regulator is required.