2 replacing the fuse, 3 troubleshooting, Warning – Furuno FA-30 User Manual
Page 22
14
3.2
Replacing the Fuse
The fuse (2A) inside the FA-30 protects it from overcurrent and equipment fault. If the
unit cannot be powered, that is, the PWR (power) LED is off, the fuse may have blown.
If this happens, turn off the power to the FA-30, open the cover and check the fuse. If
the fuse has blown, find out the reason before replacing it. If it blows again after re-
placement, contact a FURUNO agent or dealer for advice.
3.3
Troubleshooting
The troubleshooting table below provides typical operating problems and the means
to restore normal operation. If you cannot restore normal operation, do not attempt to
check inside the receiver; there are no user serviceable parts inside the receiver.
Part
Type
Code No.
Fuse (2A)
FGMB AC125V 2A PBF
000-157-479-10
Troubleshooting table
Symptom
Problem
Remedy
Receiver cannot be
powered.
Fuse inside the receiver may
have blown.
Replace the fuse.
Cannot receive.
• VHF antenna may have
loosened.
• Antenna or its cabling may be
damaged.
• Rx channel is malfunctioning.
• Check if the antenna is firmly
fastened.
• Check the antenna and its
cabling for damage.
• Confirm the channel setting.
WARNING
Use the proper fuse.
Use of a wrong fuse can result in damage
to the equipment and cause fire.