8

COM port setup

5. Click COM PORT Setup to show the COM Port Setup menu.

6. The default setting for Data Type is IEC61162, which is suitable for most installa-

tions. If change is necessary, click the Data Type drop-down list and choose data
type as applicable, among the following choices.

IEC61162: Transmit and receive IEC61162 format data via COM port. (P sen-
tences are received but not transmitted.)
IEC61162+ P-sentence: Transmit and receive IEC61162+P sentences format
data via COM port.
Off: FA-30 transmits no data.
With the radio buttons at RX Speed, choose how RX speed is regulated, Auto or
Manual. For manual, choose speed from the drop-down list.

Note: Tx speed is fixed at 38400 bps.

7. Click OK to confirm setting.
8. Click "<

(default=IEC61162)