3.1 Data Space

C141-E163

3-3

Table 3.1

Zone layout and track capacity

Cylinder

Zone

MAP3147FC

MAP3735FC

Byte/track

Sector/track

0

0 - 1,120

479,232

936

1

1,121 - 4,117

465,920

910

2

4,118 - 6,078

459,264

897

3

6,079 - 9,075

452,608

884

4

9,076 - 12,884

439,296

858

5

12,885 - 16,077

425,984

832

6

16,078 - 19,270

412,672

806

7

19,271 - 21,637

402,432

786

8

21,638 - 24,354

399,360

780

9

24,355 - 27,561

379,392

741

10

27,562 - 29,256

372,736

728

11

29,257 - 32,351

359,424

702

12

32,352 - 34,942

346,112

676

13

34,943 - 37,855

330,240

645

14

37,856 - 41,062

319,488

624

15

41,063 - 43,961

299,520

585

16

43,962 - 46,342

284,672

556

17

46,343 - 47,925

46,343 - 47,995

272,896

533

Note: When the logical data block length is 512 bytes, the sector/track capacity indicates above amount

(1)

User space

The user space is a storage area for user data. The data format on the user space (the length of data
block and the number of data blocks) can be specified with the MODE SELECT or MODE SELECT
EXTENDED command.

The default value of cylinders in the user space is MAP3147 FC = 47,926, MAP3735 FC = 47,996.
These also equal the maximum cylinders number for each series. The user can also specify the
number of logical data blocks to be placed in the user space with the MODE SELECT or MODE
SELECT EXTENDED command. When the number of logical data blocks is specified, as many
cylinders as required to place the specified data blocks are allocated in the user space.