trouBlesHootING

Continued

OBSERVED PROBLEM

Dark residue on logs or inside

of fireplace

POSSIBLE CAUSE

1. Improper log placement

2. Air holes at burner inlet

blocked

3. B u r n e r f l a m e h o l e s

blocked

4. Improper venting or exces-

sive blockage

5. Excessive amounts of

embers and pan material

REMEDY

1. Properly locate logs

2. Clean out air holes at burn-

er inlets. Periodically repeat

as needed

3. Remove blockage or re-

place burner

4. Have the vent system in-

spected, including the ter-

mination cap. Remove any

restrictions or obstruction

5. Clear excess embers until

a minimum gap of 1/2"

remains under the grate