beautypg.com

Troubleshooting – FMI PFS P324E User Manual

Page 23

background image

www.fmiproducts.com

108794-01G

23

trouBlesHootING

Continued

WARNING: If you smell gas

• Shut off gas supply.

• Do not try to light any appliance.

• Do not touch any electrical switch; do not use any phone in your

building.

• Immediately call your gas supplier from a neighbor’s phone. Fol-

low the gas supplier’s instructions.

• If you cannot reach your gas supplier, call the fire department.

IMPORTANT: Operating fireplace where impurities in air exist may create odors. Cleaning

supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles,

etc., create fumes. These fumes may mix with combustion air and create odors.

OBSERVED PROBLEM

No gas to burner, although

wall switch and valve are set

to the ON position

Frequent pilot outage

Fireplace produces a clicking/

ticking noise after burner is lit

or shut off

Fireplace produces unwanted

odors

Gas odor even when equip-

ment shutoff valve is in OFF

position

Gas odor during combustion

POSSIBLE CAUSE

1. Wall switch wires defective

or too long

2. Thermopile not generating

sufficient voltage

1. Pilot flame may be too low,

causing safety pilot to “drop

out”

2. Improper venting or exces-

sive blockage

1. Metal expanding while

heating or contracting while

cooling

1. Fireplace burning vapors

from paint, hair spray,

glues, etc. (See IMPOR-

TANT statement above)

2. For propane/LP gas, low

fuel supply

3. Gas leak.

See Warning

statement at top of page

1. Gas leak.

See Warning

statement at top of page

2. Control valve defective

1. Foreign matter between

control valve and burner

2. Gas leak.

See Warning

statement at top of page

REMEDY

1. Check electrical connec-

tions

2. See Pilot will not stay lit,

page 22

1. Clean and adjust pilot flame

for maximum flame im-

pingement on thermopile

2. Have the vent system in-

spected, including the ter-

mination cap. Remove any

restriction or obstruction

1. This is normal with most

fireplaces. If noise is ex-

cessive, contact qualified

service person

1. Ventilate room. Stop us-

ing odor causing products

while fireplace is running

2. Contact local propane/LP

supplier

3. Locate and correct all leaks

(see Gas Line Hook-Up,

page 12)

1. Locate and correct all leaks

(see Gas Line Hook-Up,

page 12)

2. Replace control valve

1. Take apart gas tubing and

remove foreign matter

2. Locate and correct all leaks

(see Gas Line Hook-Up,

page 12)

This manual is related to the following products: