5 gas connections (cont.), 5 gas specifications, Australian requirements – Frymaster DEAN FPD65 User Manual
Page 19: Non-ce (altitudes of 2000 feet or less)
HIGH EFFICIENCY DECATHLON (HD) SERIES GAS FRYERS
CHAPTER 3: INSTALLATION
3-6
3.5 Gas Connections (cont.)
WARNING
Do not attach accessories to this fryer unless fryer is secured from tipping. Personal
injury may result.
2. The fryer must be restrained by means independent of the flexible coupling or
connector in order to limit the movement of the fryer. Restraining brackets are
located on the back panel of the fryer for the attachment of restraints.
3. If disconnection of the restraint is necessary, this restraint must be reconnected after
the fryer has been returned to its originally installed position.
I. After hook-up, bleed the gas line of air to ensure that the pilot light will ignite quickly.
AUSTRALIAN REQUIREMENTS
To be installed in accordance with AS 5601 / AG 601, local authority, gas, electricity, and any other
relevant statutory regulations.
3.5 Gas Specifications
NON-CE (Altitudes of 2000 feet or less)
EQUIPMENT
PRESSURE
MODEL
INPUT
(BTU)
GAS
TYPE
ORIFICE
(MM)
ORIFICE
PART NO.
QTY
MBAR INCH
W.C.
D20G 50
NAT
LP
2.18(#44)
1.40(#54)
810-2050
810-2324
2
2
10
27.5
4
11
D50G 85
NAT
LP
2.08(#45)
1.32(#55)
14-0067-45
810-2441
4
4
10
27.5
4
11
D50G(HP) 120
NAT
LP
2.53(#39)
1.51(#53)
810-2048
810-2059
4
4
10
27.5
4
11
D50GDDHP 115
NAT
LP
2.44(#41)
1.51(#53)
14-0067-41
810-2059
4
4
10
27.5
4
11
D60G 112
NAT
LP
2.08(#45)
1.32(#55)
14-0067-45
810-2441
5
5
10
27.5
4
11
D60G(HP) 150
NAT
LP
2.53(#39)
1.51(#53)
810-2048
810-2059
5
5
10
27.5
4
11
D80G 122
NAT
LP
2.26(#43)
1.40(#54)
810-2049
810-2324
5
5
10
27.5
4
11
D80G(HP) 165
NAT
LP
2.58(#38)
1.61(#52)
810-2062
810-2063
5
5
10
27.5
4
11
HD50G 95
NAT
LP
2.26(#43)
1.40(#54)
810-2938
810-2939
4
4
10
27.5
4
10
HD60G 125
NAT
LP
2.26(#43)
1.40(#54)
810-2938
810-2939
5
5
10
27.5
4
10
NOTE: Outlet gas pressure must be adjusted strictly within the above requirements 5 to 10 minutes after the appliance is operating.
(Pilot Flame Adjustment: Turn the pilot adjustment screw clockwise/counter-clockwise until the desired flame-volume is achieved.)