Frymaster GEN II LOVTM BIELA14 User Manual
Page 74
![background image](/manuals/103257/74/background.png)
7-6
is missing
E12
ERROR RETURN VALVE NOT OPEN
Return valve was trying to open and confirmation
is missing
E13
ERROR RETURN VALVE NOT CLOSED
Return valve was trying to close and confirmation
is missing
E14
ERROR AIF BOARD
MIB detects AIF missing; AIF board failure
E15
ERROR MIB BOARD
Cooking computer detects MIB connections lost;
Check software version on each computer. If
versions are missing, check CAN connections
between each computer; MIB board failure
E16
ERROR AIF PROBE
AIF RTD reading out of range
E17
ERROR ATO PROBE
ATO RTD reading out of range
E18 Not
used
E19
M3000 CAN TX FULL
Connection between computers lost. Check for
loose CAN cables between computers and MIB
board. Check software version by pressing the
TEMP button with the computers displaying OFF.
If a computer displays only M3000 software, the
computer may be defective.
E20
INVALID CODE LOCATION
SD card removed during update
E21 FILTER PAD PROCEDURE ERROR
(Change Filter Pad)
25 hour timer has expired or dirty filter logic has
activated
E22
OIL IN PAN ERROR
The MIB has reset the oil in pan flag.
E23
CLOGGED DRAIN (Gas)
Vat did not empty during filtration
E24
AIF BOARD OIB FAILED (Gas)
Oil is back sensor failed.
E25
RECOVERY FAULT
Recovery time exceeded maximum time limit.
E26
RECOVERY FAULT CALL SERVICE
Recovery time exceeded maximum time limit for
two or more cycles.
E27
LOW TEMP ALARM
Oil temperature has dropped lower than 15°F
(8°C) in idle mode or 45°F (25°C) in cook mode.