4-23
4.11.5 Pan to Waste
Pan to waste selection is an option that allows bulk oil systems to pump excess oil in the pan to the
bulk oil waste tanks without draining the existing oil in the frypot.
1. With the computer
OFF, press and hold the filter button for the vat to be
refilled for three seconds.
The computer displays
filter menu for three seconds, changing to MAINT Filter.
2. Use the
t and
ubuttons to scroll to PAN TO WASTE.
3. With
PAN TO WASTE displayed, press the (1 yes) button to
continue.
The computer displays
PAN TO WASTE? alternating with yes no.
4. Press the
(yes) button and go to Section 4.10.4..3 page 4-18 and
continue after step 6 or press (2
NO) button to exit to filter menu.
4.12 Programming Level One
Level one programming is used to enter new products, control when AIF (auto intermittent filtration)
is disabled and perform deep clean (boil-out) and high-limit test.
To enter Level 1 programming mode:
1. With the computer
OFF, press the TEMP and INFO buttons
simultaneously for THREE seconds until
LEVEL 1 is displayed; a chirp
sounds.
The computer displays
ENTER Code.
2. Enter 1234.
1
2
3
4
(1234)
The computer displays
level 1 program for three seconds changing to Product
selection.