3 speed/water temperature sensor calibration – Furuno FCV-1150 User Manual

Page 23

background image

14

ENTERing transducer data by transducer specifications

To connect the transducers which are not programmed, do as follows:

Note: The transducers of 53 - 65 kHz, 111 to 139 kHz and 171 - 183 kHz cannot be connected to
the FCV-1150
because of noise.

1. At the XDCR Setting dialog box, select "XDCR Select" and press the ENTER key.

The following screen appears.

2. Press T to select "Manual", and then press the ENTER key.
3. If a high frequency transducer is fitted, press T to select "HF Connection" and then press the

ENTER key.

4. Press S to select "Connected" and then press the ENTER key.
5. Press T to select "Freq" and then press the ENTER key.

6. Press T or S to set the value for the frequency which is connected and then press the

ENTER key.

7. Press T to select "Band width" and then press the ENTER key.
8. Press T or S to set the value for the band width and then press the ENTER key. If the band

width is not ENTERed manually, it is automatically set to 1/10 of the transducer frequency.

9. If a low frequency transducer is fitted, repeat steps 3 to 8.

Note: Leave the "Tx Power" at "Auto".

10.Press and hold down the [

/BRILL] key to turn off the power.

3.3

Speed/Water Temperature Sensor Calibration

If the optional speed and/or water temperature sensor is connected, set up as follows:

1. Turn on the power and press the MENU key.

The main menu and sub-menu appears.

2. Press T to select "System" and "Calib" and then press the ENTER key.

XDCR Type

Manual

Connected
Not connected

--- kHz