2.2

Wiring Standard Equipment

Power cable

This video sounder is designed to be powered with 12-24 VDC power. Use the cable DPYCY-1.5
(Japan Industry Standard) or equivalent.

Power cable DPYCY-1.5 (JIS cable)

Transducer

Separate the transducer cable well away from power cables to prevent interference. Connect the
cable to the transducer port (for high frequency and/or low frequency) at the rear of the display
unit. Fabricate the cable as below.

Fabrication of transducer cable

Note: FCV-1150 cannot accept the transducers of 53 - 65 kHz, 111 to 139 kHz and 171 - 183 kHz.

Approx. 70

3

Armor

Sheath

Vinyl tape

6

Clamp armor with cable clamp.

Climp-on lug

FV2-M4

30

Sheath

Conductor
S = 1.5 mm
Ǟ = 1.56 mm
(AWG16)

2

DPYCY-1.5

Armor

Sheath

Ǟ =

13.7 mm

Shield

Vinyl tape

Sheath

Wrap shield around cores 30 mm and cut excess shield.
Clamp here with cable clamp.

Extract cores from here and cut inner materials.

30

6

Approx. 130