beautypg.com

Frymaster Dean FPHD User Manual

Page 27

background image

HIGH EFFICIENCY DECATHLON SERIES GAS FRYERS

CHAPTER 1: SERVICE PROCEDURES

1-22

1.7.8 Replacing the Frypot

(cont.)

10. Remove screws securing flue cap to frypot (access from above; a nut-driver with an extension or

long screwdriver is required). Use care not to drop the screws into the flues. If this happens, the
screws can be retrieved when the flue is removed (Step 16). Use a screwdriver or similar tool to
free flue cap from frypots. Remove flue cap by lifting up and off of fryer.


Remove the screws (arrow) securing the flue cap
to the frypot on the long edge. There will be two or
three screws depending on configuration. (view
from above, looking down into flue)

Remove the screws (arrows) securing the flue
cap to the frypot on the short edge. There will be
two screws on each end of the flue. (view from
above, looking down into flue)




11. Remove gas manifold pipe for access to gas

manifold shield by disconnecting at the unions.
Ensure gas supply is shut off and supply line is
disconnected prior to removing. Set gas
manifold aside. Remove screws securing gas
manifold shield. Remove shield to access oil-
return plumbing components connected to the
frypots.

NOTE: For units without built-in filtration
skip the steps pertaining to removal and
replacement of oil-return plumbing.



















Removing gas manifold shield.