HIGH EFFICIENCY DECATHLON SERIES GAS FRYERS

CHAPTER 1: SERVICE PROCEDURES

1-13

1.7.3 Replacing the Temperature Probe; Computer-equipped Fryers

(cont.)

6. Remove the burner shield by loosening the

screw on each end.


7. Remove the burner rail by loosening the

screw on each end. The burner rail secures
the burners in the burner manifold. Be
careful to ensure that the burners do not fall
out of the gas manifold, as they might be
damaged and dented.




8. Remove the burners to gain access to the

temperature probe and to ease frypot
removal. Lean each burner slightly away
from the frypot to clear the burner seal
(metal box attached to frypot). Then, pull
the burner up and off of the orifice. The
burners should be easy to remove and do
not require force.






9. Loosen and unscrew the compression nut

and the pass-through nut completely from
the frypot. Proceed to the next step before
removing the probe from the frypot.











Remove the burner rail and burner shield.










Loosen and unscrew completely the compression
nut (bottom arrow), then the pass-through nut (top
arrow).

Remove burners to gain access to temperature
probe (arrow).