beautypg.com

Specifications, Electrical, Plumbing – Follett VU300 User Manual

Page 4

background image

Specifications

Electrical

Each dispenser requires a separate circuit with electrical disconnect within 10 ft (6m). Equipment ground required.
Standard electrical – 115V, 60Hz, 1 phase. Maximum dispenser fuse – 20 amps, maximum icemaker fuse – 20
amps each. Cord and plug provided with each dispenser.

Model

Icemaker

Dispenser

number

amperage

amperage

Single-sided models

VU300M series

11.0 amps ea (2)

6.0 amps

VU300B series

11.0 amps ea (2)

7.0 amps

Dual-sided models

VU30020MD series

11.0 amps ea (2)

8.0 amps

Plumbing

Dispenser

3/4" PVC pipe nipple for bin drain

3/4" PVC pipe nipple for drain pan drain

1" ID hose for beverage bath drain

Beverage connections

1/4" ID syrup beverage hose

3/8" ID carbonated water beverage hose

3/8" ID plain water beverage hose

Note: Drains should be hard piped and insulated. Maintain at least 1/4" per foot (6mm per 304mm run)

slope on drain line run.

Water disconnect within 10 feet (3m) of dispenser is suggested for automatic load units.

Follett recommends use of a Follett water filter (part# 00130229) on icemakers connected

to automatic fill dispensers.

Icemaker

Refer to detailed specifications in icemaker installation manual

packed

with

icemaker

5