Field Controls TM-2000 User Manual
Whole house humidifier
WHOLE HOUSE HUMIDIFIER
Model: TM-2000
The TM-2000 Humidifier is activated by heated air being produced by your furnace. Its thermal sensing circuitry
monitors the temperature of the heated air. When the air is warm enough, the Housing Assembly’s electric
water valve is actuated, opening to allow cold water from your plumbing system to be atomized into a fine mist.
This mist is discharged into the heated air by the Remote Nozzle Bracket Assembly, where it immediately
evaporates and is distributed throughout your household. The TM-2000 is supplied water from your plumbing
system by the Saddle Valve Assembly, and is safely powered with reduced voltage by the 120/24 VAC
Transformer, which plugs into an ordinary 120-volt wall outlet.
The TM-2000 is ideal for use with conventional gas or oil forced-air central heating systems.
WARNING: The TM-2000 is not be used on 90+ condensing furnaces, electric heat pumps or homes
with well-water systems.
I
TEMS INCLUDED IN KIT
: (DO NOT INSTALL HUMIDIFIER IF ALL OF THESE ITEMS ARE NOT PRESENT!)
Housing Assembly
Remote Nozzle Bracket
Plastic Tubing (3 - 10' Sections)
Saddle Valve Assembly
Housing Mounting Template
Includes 5 Each: Compression Nuts, sleeves, and inserts
Remote Mounting Template
Mounting Components
Power Supply Wire
Includes: (4) #8-15 X 3/4" Hex Head Housing
Quick Connect Terminals (2)
(3) #8-15 X 1/2" Hex Head Remote
120/24 VAC Transformer
Bracket Mounting Screws
Instruction Manual
(3) #8 Speed Nuts For Remote Bracket Mounting.
O
PTIONAL ACCESSORIES
:
Air Booster Activator Kit
Humidistat
NOTE:
The TM-2000 is designed to operate on normal city water supply
pressure. If any other type of water supply is to be used it must be capable of
providing a minimum pressure of 50 psi.
DO NOT DESTROY
READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE OF REPLACEMENT PARTS, OPTIONAL
COMPONENTS, AND TROUBLESHOOTING INFORMATION.
120VAC/24VAC
Transformer
Plastic Tubing (3-10’ Sections)
10’ Power Supply Wire
Saddle Valve Assembly
English ...... Page 1
Français..... Page 8
Espanõl ..... Page 14
Housing Assembly
Remote
Nozzle Bracket
PRODUCT QUESTIONS…
CALL FIELD FIRST
Phone: (252)522-3031
E-mail:
for answers on product maintenance,
operation or replacement part questions.