background image

Your HRV/ERV system produces a dehumidifying effect when

outdoor humidity levels are lower than indoor humidity levels.

These conditions occur normally when outdoor termperatures are

below 60°F. An additional dehumidification effect is achievable

with the Optional Dehumidistat (Part DH1).
The Optional DH1 Control may be combined with the Healthy
Home System Control (HHSC). The DH1 will initiate high speed
ventilation when the moisture level in the home exceeds the set
point on the control. Once the humidity in the house is reduced,
the HRV will revert back to the HHSC automatic setting. The
Dehumidistat should be set to OFF for all seasons except the
heating season.

Dehumidistat (Part DH1)

Healthy Home System Control (HHSC)

Dehumidistat Indicator

LEDs

Set to the desired humidity

level. High speed ventilation

will initiate when the indoor

moisture level exceeds the set

point on the control.

Dehumidistat

Adjust button

The Healthy Home System Control (HHSC) activates the

HRV/ERV automatically to deliver fresh air into your home.

Setting the Control

The duration of the ventilation rate is adjustable on the HHSC.

Your installer sets up this control during the installation of your

system . Refer to the instructions that came with the HHSC for the

setup information.

The Healthy Home System™ Control (HHSC)