Setting up the hhsc control, The healthy home system™ control (hhsc) – Field Controls Heat Recovery Ventilator FC95HRV. User Manual

Page 24

background image

24

Installation of the HHSC with the DH1 and 20/40/60 Minute Timers (test a)

1

2

3

4

5

6

7

8

9

10

LO

ON

R

Y

G

HI

C

NO

NC

BK

FACTORY-INSTALLED JUMPER
DO NOT REMOVE

LO

HI

24C

*

R

C

Wt

Gt

Gf

V

HHSC CONTROL

R

C

W

Y

G

R

Y

W

G

THERMOSTAT

FURNACE OR
HEAT PUMP

HRV/ERV WIRING TERMINALS

12V/24 VAC Field wiring, 20 AWG min. required

* Connect V Terminal on the HHSC Control to the Hi Terminal (instead of Lo) for a shorter ventilation period.
** One DH-1 Dehumidistat and/or one or more VTC timer controls may be connected as shown. Connect all

Red, Yellow, and Green control terminals to the corresponding HRV/ERV terminals.

%

80

20

R

Y

G

Y

R
G

Y

R

G

VTC VENT TIMER CONTROL
(OPTIONAL)**

VTC VENT TIMER CONTROL
(OPTIONAL)**

DH1 DEHUMIDISTAT
(OPTIONAL)**

Setting up the HHSC Control

The duration of the ventilation rate is adjustable
on the Healthy Home System Control™ (HHSC).
Refer to the instructions that accompanied the
HHSC for setup information.

The Healthy Home System™ Control (HHSC)