beautypg.com

Frymaster CF Series User Manual

Page 43

background image

CF SERIES GAS FRYERS

CHAPTER 6: OPERATOR TROUBLESHOOTING

6-3

6.2 Troubleshooting Fryers with Solid State (Analog), Digital, or CM III.5

Controllers (cont.)


PROBLEM

PROBABLE CAUSES

CORRECTIVE ACTION

CM III.5 will not go

into programming

mode. (cont.)

B. Failed controller.

B. If available, substitute controller

known to be good for suspect
controller (see Section 6.6). If
fryer operates normally, order
replacement controller from
FASC.

A. Setpoint incorrect.

A. Verify that setpoint has been

properly entered.

B. Temporary controller malfunction

caused by voltage surge.

B. Disconnect unit from electrical

power, wait at least one minute,
and reconnect unit to the power
supply.

CM III.5 displays

as it comes out of

melt cycle

OR

Heating mode

indicator does not

come on at all.

C. Failed controller.

C. If available, substitute controller

known to be good for suspect
controller (see Section 6.6). If
fryer operates normally, order
replacement controller from
FASC.

A. Burner is not lit.

A. Refer to Burner does not light

problem on the following page in
Sec. 6.3.

Heating mode

indicator is on but

fryer is not heating

properly. B. Failed controller.

B. If available, substitute controller

known to be good for suspect
controller (see Section 6.6). If
fryer operates normally, order
replacement controller from
FASC.