beautypg.com

Adapting to different types of gas – Indesit K3G52S User Manual

Page 19

background image

19

GB

! If one or more of these conditions is not fulfilled or
if the cooker must be installed according to the
conditions listed for class 2 - subclass 1 appliances
(installed between two cupboards), the flexible steel
hose must be used instead (

see below).

Connecting a flexible jointless stainless steel pipe
to a threaded attachment

Make sure that the hose and gaskets comply with
current national legislation.
To begin using the hose, remove the hose holder on the
appliance (the gas supply inlet on the appliance is a
cylindrical threaded 1/2 gas male attachment).

! Perform the connection in such a way that the hose
length does not exceed a maximum of 2 metres,
making sure that the hose is not compressed and
does not come into contact with moving parts.

Checking the connection for leaks

When the installation process is complete, check
the hose fittings for leaks using a soapy solution.
Never use a flame.

Adapting to different types of gas

It is possible to adapt the appliance to a type of gas
other than the default type (this is indicated on the
rating label on the cover).

Adapting the hob

Replacing the nozzles for the hob burners:
1. Remove the hob grids and slide the burners off
their seats.

2. Unscrew the nozzles using a
7 mm socket spanner (

see

figure), and replace them with
nozzles suited to the new type
of gas(

see Burner and nozzle

specifications table).
3. Replace all the components
by following the above

instructions in reverse.

Adjusting the hob burners’ minimum setting:
1. Turn the tap to the minimum position.
2. Remove the knob and adjust the regulatory
screw, which is positioned inside or next to the tap
pin, until the flame is small but steady.
! If the appliance is connected to a liquid gas
supply, the regulatory screw must be fastened as
tightly as possible.

3. While the burner is alight, quickly change the position
of the knob from minimum to maximum and vice versa
several times, checking that the flame is not
extinguished.

! The hob burners do not require primary air adjustment.

TECHNICAL DATA

Oven dimensions
(HxWxD)

34x39x41 cm

Volume

54 l

Useful
measurements
relating to the oven
compartment

width 42 cm
depth 44 cm
height 23 cm

Power supply voltage
and frequency

see data plate

Energy Label

Declared energy consumption for
Natural convection Class
Heating mode: Convection
Energy consumption for Forced
convection heating mode:
Fan assisted

Burners

may be adapted for use with any
type of gas shown on the data
plate, which is located inside the
flap or, after the oven
compartment has been opened,
on the left-hand wall inside the
oven.

EC Directives: 2006/95/EC dated
12/12/06 (Low Voltage) and
subsequent amendments -
2004/108/EC dated 15/12/04
(Electromagnetic Compatibility)
and subsequent amendments -
2009/142/EC dated 30/11/09
(Gas) and subsequent
amendments - 93/68/EEC dated
22/07/93 and subsequent
amendments - 2002/96/EC.
1275/2008 (Stand-by/ Off mode)

This manual is related to the following products: