Frymaster 1814E User Manual
Page 23
4-8
4.5 Operating the Filter
4.5.1 Filter Operation
See Section 4.3.2, Assembling the Filter, and Section 4.3.3, Installing the Filter, for the appropriate
filter preparation procedure.
CAUTION
NEVER operate the filter unit unless cooking oil is at operating temperature (~350°F/
~177°C).
1. Ensure the filter pan assembly is prepared as described in Section 4.3.2, Assembling the Filter.
Follow the instructions in the controller manual for filtering.
2. Remove fry baskets from frypot and skim any
large debris from the oil. Use extreme
caution, as oil is at or near operating
temperature (~350°F/~177°C).
3. Remove the basket support rack from the
frypot using the Fryer’s Friend clean-out rod.
Stir the oil with the frypot/filter brush to
suspend debris prior to draining.
4. After ensuring the filter pan is correctly
positioned under the drain tubes, move the
red handle to the open position (right) to
drain the frypot into the filter pan. Drain
ONLY ONE frypot at a time. The filter
pan is designed to hold the contents of
ONE frypot ONLY. If necessary, use the
Fryer's Friend clean-out rod to clear the
drain from inside the frypot.
DANGER
Do not drain more than one frypot at a
time into the built-in filtration unit to
avoid overflow and spillage of hot oil.
Prior to filtering, skim any
large debris from oil in
frypot.
Removing basket support
rack from frypot prior to
filtering.
Move the red drain valve
handle into the open
position (right).
DANGER
NEVER attempt to clear a clogged drain
valve from the front of the valve! Hot oil
will rush out creating the potential for
severe burns.