Frymaster 1814E User Manual

Page 11

background image

2-3

2.2 Power

Requirements

Three (3) Phase Requirements

MODEL VOLTAGE

WIRE

SERVICE

MINIMUM WIRE

SIZE

AWG (mm)

AMPS

(per leg)

1814E 14kW

208 3 6

(4.11)

39

1814E 14kW

240 3 6

(4.11)

34

1814E 14kW

480 3 8

(2.59)

17

1814E 14kW

220/380

4 6

(4.11)

21

1814E 14kW

240/415

4 6

(4.11)

20

1814E 14kW

230/400

4 6

(4.11)

21

1814E 17kW

208 3 6

(4.11)

48

1814E 17kW

240 3 6

(4.11)

41

1814E 17kW

480 3 6

(4.11)

21

1814E 17kW

220/380

4 6

(4.11)

26

1814E 17kW

240/415

4 6

(4.11)

24

1814E 17kW

230/400

4 6

(4.11)

25

1814E 22kW

208 3 4

(5.19)

61

1814E 22kW

240 3 4

(5.19)

53

1814E 22kW

480 3 6

(4.11)

27

1814E 22kW

220/380

4 6

(4.11)

34

1814E 22kW

240/415

4 6

(4.11)

31

1814E 22kW

230/400

4 6

(4.11)

32

Single Phase Requirements

MODEL VOLTAGE

WIRE

SERVICE

MINIMUM WIRE

SIZE

AWG (mm)

AMPS

(per leg)

1814E 14kW

208 2 3

(5.83)

68

1814E 14kW

240 2 4

(5.19)

59

1814E 14kW

480 2 8

(3.26)

30

NOTICE

If this appliance is permanently connected to fixed wiring, it must be connected by
means of copper wires having a temperature rating of not less than 167°F (75°C).

DANGER

This appliance must be connected to a power supply having the same voltage and
phase as specified on the rating plate located on the inside of the appliance door.

DANGER

All wiring connections for this appliance must be made in accordance with the
wiring diagram(s) furnished with the appliance. Refer to the wiring diagram(s)
affixed to the inside of the appliance door when installing or servicing this
equipment.


2.3

Positioning the Fryer

DANGER

No structural material on the fryer should be altered or removed to accommodate
placement of the fryer under a hood. Questions? Call the Frymaster Service Hotline
at 1-800-551-8633.