7.9 Trouble Shooting

Problem

Solution

Evaluationboard does not
initialize after power-on.
LED D10 (Power indicator) does
not light up and the LC-display
remains empty.

Check voltage supply and jumpers :

The voltage on DC-Power plug

should be in the range of 9-12V. The
plug should have + on shield and – on
the center. LED D10 should light up
after switching on the board. Use a
multimeter to see whether 5V are
present on the Vcc/Gnd terminals (TP2
and TP3).

Check jumper positions according to

table 1 (Esp. : JP1 – JP7) !

Remove all user extensions on the

board to avoid shorts !

Evaluationboard stays in reset.
LED D11 (Reset indicator) ligths
up permanently.

LED D11 (Reset) should flash. If D11

lights up permantantly, the voltage is too
low (below 4.25V) - Increase the voltage
to solve the problem.

JP33 (DTR reset) should be left

open. This option allows to reset the
board from a connected PC using the
DTR line (not used by Softune WB).

Remove all user extensions on the

board to avoid shorts or leakage
currents !

After power-on, the initial
monitor-message is not shown
on the LCD.

Check JP34 (default-mode) : This

jumper should be in the lower position
(Monitor mode). In the upper position,
the board will call the user program in
Flash-ROM directly and will not show
the message.

Maybe the monitor-kernel has been

destroyed. Try to re-program the kernel
as desribed in the „flash programming“-
section.

Check all jumper positions (table 1).

Adjust the LCD contrast using

potentiometer RV1.

The communication from
Softune Workbench to the

Make sure your COM-port number

and the baudrate settings are correct