5

Care and maintenance

To remove filter

Simply turn the unit off and pull the filter frame up and towards you (See
Figure 6). Clean with warm water and a mild detergent, rinse, dry, and
replace by sliding the filter back into position behind the front panel.

Figure 6

READ THIS FIRST! Electrical Requirements

IMPORTANT: Before you begin the actual installation of the air conditioner,
be sure your electrical requirements are as described below. Consult an

electrical professional as necessary to insure home wiring is per local
electrical codes.

CIRCUIT PROTECTION - An overloaded circuit will invariably cause mal-
function or failure of an air conditioner, therefore, it is necessary that the
electrical protection is adequate. All portable chassis models require a 15
amp fuse or circuit breaker for over-amperage protection. Due to momen-
tary high current demand when your air conditioner is started, use a "TIME

DELAY" fuse or a HACR type circuit breaker. Consult your dealer or power
company if in doubt.

Your air conditioner must be connected to a power supply with the same A.C.

voltage and hertz as marked on the unit nameplate. Only alternating current
(A.C.), no direct current (D.C.), can be used.

The power cord has a plug with a grounding prong of approved type and a

matching plug receptacle with ground is required. Refer to page 3 for the
correct type of plug receptacle for your model.

WARNING: NEVER CUT OR REMOVE THE GROUNDING PRONG

FROM PLUG. NEVER USE EXTENSION CORDS TO OPERATE AN AIR

CONDITIONER.

Items required for installation

(provided in straight cooling units only)

ITEM NO.

DESCRIPTION

QTY.

1
2
3
4

SCREW, SHEET METAL, #8 x "
SCREW, PHILLIPS, TRUSS HEAD, #8 x ½"
SCREW, HEX, #8 x "
SCREW, PHILLIPS, #8 x 1 ¼"

8

4

10

2

5
6

GRAY GASKET, FOAM, 1" x 1 ½" x 42"
WHITE GASKET, FOAM, 1" x 1 ½" x 48"

1
1

Installation instructions

NOTE: This section includes installation instructions for window mount and thru-the-wall mount methods. X-Star

®

heat/cool units are designed for permanent

thru-the-wall installation. Mounting the unit in a window will require a window mounting accessory kit, available through your Fried rich dealer.

ITEM NO.

DESCRIPTION

QTY.

7
8

LEFT SIDE CURTAIN ASSEMBLY
RIGHT SIDE CURTAIN ASSEMBLY

1
1

9

10

11

DECORATIVE FRONT PANEL
CABINET OR SLEEVE
AIR CONDITIONING UNIT

1
1
1

ITEM 1

ITEM 2

ITEM 3

ITEM 4

ITEM 5

ITEM 6

ITEM 7

ITEM 8

ITEM 9

ITEM 10

ITEM 11

Electrical Shock Hazard

Make sure your electrical receptacle has the
same configuration as your air conditioner’s
plug. If different, consult a Licensed Electrician.

Do not use plug adapters.
Do not use an extension cord.
Do not remove ground prong.

Always plug into a grounded 3 prong outlet.
Failure to follow these instructions can result in
death, fire, or electrical shock.

WARNING