beautypg.com

8 test pattern, 9 memory clear – Furuno Ls4100 User Manual

Page 29

background image

23

4. The ROM, RAM and NMEA port are

checked, with the results shown as
OK or NG (No Good). For any NG,
request service. (A special connector
is required to test the NMEA port.
Nothing appears if no connector is
connected.)

5. The squares at the right side of the

test display are for checking the
controls. Press each key and the
arrows on the Cursor Pad one by
one. A control’s corresponding
on-screen square “lights” in black if
the control is normal.

6. To return to the Installation menu,

press the [MENU/ESC] key three
times.

7. To restore normal operation, turn off

the power and turn it on again.

3.8 Test

Pattern

This feature tests for proper display of
tones.

1. On the Installation menu, press▼ to

choose LCD PATTERN.

2. Press ► to start the test. The entire

screen is black.

3 Press ► again and the screen turns

white.

4. Press ► again and the screen

shows a four-toned display.

5. Press ► again to return to the

Installation menu.

6. To restore normal operation, turn off

the power and then it on again.

WHITE

FOUR-TONE

BLACK

Test patterns

3.9 Memory

Clear

The memory can be cleared to start
afresh with default menu settings.

1. At the installation menu, press ▼ to

choose MEMORY CLEAR.

2. Press ► to open the options

window.

: YES
: NO

Clear memory display

3. Press ▲ to clear the memory. Beeps

are generated while the memory is
being cleared.

4. To restore normal operation, turn off

the power and then turn it on again.